Lambda-IgLC anticorps (APC)
-
- Antigène Tous les produits Lambda-IgLC
- Lambda-IgLC (lambda Light Chain (Lambda-IgLC))
-
Reactivité
- Humain
-
Hôte
- Souris
-
Clonalité
- Monoclonal
-
Conjugué
- Cet anticorp Lambda-IgLC est conjugé à/à la APC
-
Application
- Flow Cytometry (FACS)
- Specificité
- The mouse monoclonal antibody 1-155-2 recognizes lambda light chains (22.5 kDa) of human immunoglobulin.
- Réactivité croisée (Details)
- Human
- Purification
- Purified antibody is conjugated with activated allophycocyanin (APC) under optimum conditions and unconjugated antibody and free fluorochrome are removed by size-exclusion chromatography.
- Immunogène
- Human IgA1 lambda myeloma protein
- Clone
- 1-155-2
- Isotype
- IgG1 kappa
-
-
- Indications d'application
- Flow cytometry: The reagent is designed for analysis of human blood cells using 10 μL reagent / 100 μL of whole blood or 106 cells in a suspension. The content of a vial (1 ml) is sufficient for 100 tests. Extracellular and intracellular staining.
- Commentaires
-
The purified antibody is conjugated with cross-linked Allophycocyanin (APC) under optimum conditions. The conjugate is purified by size-exclusion chromatography and adjusted for direct use. No reconstitution is necessary.
- Restrictions
- For Research Use only
-
- Reconstitution
- No reconstitution is necessary.
- Buffer
- Stabilizing phosphate buffered saline (PBS), pH 7.4, 15 mM sodium azide
- Agent conservateur
- Sodium azide
- Précaution d'utilisation
- This product contains Sodium azide: a POISONOUS AND HAZARDOUS SUBSTANCE which should be handled by trained staff only.
- Conseil sur la manipulation
-
Do not freeze.
Avoid prolonged exposure to light. - Stock
- 4 °C
- Stockage commentaire
- Store at 2-8°C. Protect from prolonged exposure to light. Do not freeze.
-
-
Low levels of monoclonal small B cells in the bone marrow of patients with diffuse large B-cell lymphoma of activated B-cell type but not of germinal center B-cell type." dans: Haematologica, Vol. 95, Issue 8, pp. 1334-41, (2010) (PubMed).
: "Splenic marginal zone lymphomas appear to originate from different B cell types." dans: The American journal of pathology, Vol. 161, Issue 1, pp. 81-8, (2002) (PubMed).
: "Immunoglobulin isotype expression of normal pre-B cells as determined by immunofluorescence." dans: Journal of clinical immunology, Vol. 2, Issue 4, pp. 264-9, (1983) (PubMed).
: "
-
Low levels of monoclonal small B cells in the bone marrow of patients with diffuse large B-cell lymphoma of activated B-cell type but not of germinal center B-cell type." dans: Haematologica, Vol. 95, Issue 8, pp. 1334-41, (2010) (PubMed).
-
- Antigène
- Lambda-IgLC (lambda Light Chain (Lambda-IgLC))
- Autre désignation
- Lambda light chains (Lambda-IgLC Produits)
- Sujet
- Immunoglobulin classes share the same basic four polypeptide chain structure of two heavy chains (five heavy chains types) and two light chains (kappa, lambda, both having a molecular weight of 22.5 kDa). Kappa and lambda consist of a variable region and a constant region and can easily be differentiated by the antigenic properties of the constant region. The ratio of kappa to lambda is 70:30.,Immunoglobulin lambda, Igl
- Poids moléculaire
- 22.5 kDa
-