Chemokine (C-X-C Motif) Ligand 15 (CXCL15) Kit ELISA

CXCL15 Reactivité: Souris Colorimetric Sandwich ELISA 0.8-200 ng/mL Cell Culture Supernatant, Plasma, Serum
N° du produit ABIN1979538
  • Antigène Voir toutes Chemokine (C-X-C Motif) Ligand 15 (CXCL15) Kits ELISA
    Chemokine (C-X-C Motif) Ligand 15 (CXCL15)
    Reactivité
    Souris
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    0.8-200 ng/mL
    Seuil minimal de détection
    0.8 ng/mL
    Application
    ELISA
    Fonction
    Mouse Lungkine (CXCL15) ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Type d'échantillon
    Serum, Plasma, Cell Culture Supernatant
    Analytical Method
    Quantitative
    Specificité
    This ELISA antibody pair detects Mouse CXCL15. Other species not determined.
    Attributs du produit
    • Strip plates and additional reagents allow for use in multiple experiments
    • Quantitative protein detection
    • Establishes normal range
    • The best products for confirmation of antibody array data
    Ingrédients
    • Pre-Coated 96-well Strip Microplate
    • Wash Buffer
    • Stop Solution
    • Assay Diluent(s)
    • Lyophilized Standard
    • Biotinylated Detection Antibody
    • Streptavidin-Conjugated HRP
    • TMB One-Step Substrate
    Matériel non inclus
    • Distilled or deionized water
    • Precision pipettes to deliver 2 μL to 1 μL volumes
    • Adjustable 1-25 μL pipettes for reagent preparation
    • 100 μL and 1 liter graduated cylinders
    • Tubes to prepare standard and sample dilutions
    • Absorbent paper
    • Microplate reader capable of measuring absorbance at 450nm
    • Log-log graph paper or computer and software for ELISA data analysis
  • Indications d'application
    Recommended Dilution for serum and plasma samples2 fold
    Volume d'échantillon
    100 μL
    Plaque
    Pre-coated
    Protocole
    1. Prepare all reagents, samples and standards as instructed in the manual.
    2. Add 100 μL of standard or sample to each well.
    3. Incubate 2.5 h at RT or O/N at 4 °C.
    4. Add 100 μL of prepared biotin antibody to each well.
    5. Incubate 1 h at RT.
    6. Add 100 μL of prepared Streptavidin solution to each well.
    7. Incubate 45 min at RT.
    8. Add 100 μL of TMB One-Step Substrate Reagent to each well.
    9. Incubate 30 min at RT.
    10. Add 50 μL of Stop Solution to each well.
    11. Read at 450 nm immediately.
    Préparation des réactifs
    1. Bring all reagents and samples to room temperature (18 - 25 °C) before use. 2. Sample dilution: If your samples need to be diluted, 1x Assay Diluent D (Item K) should be used for dilution of serum/plasma/culture supernatants. The Mouse CXCL15 ELISA Kit Protocol 3 Suggested dilution for normal serum/plasma: 2 fold. Please note that levels of the target protein may vary between different specimens. Optimal dilution factors for each sample must be determined by the investigator. 3. Assay Diluent D (Item K) and Assay Diluent B (Item E) should be diluted 5-fold with deionized or distilled water before use. 4. Preparation of standard: Briefly spin the vial of Item C. Add 400 µL 1x Assay Diluent D (Item K) into Item C vial to prepare a 200 ng/ml standard solution. Dissolve the powder thoroughly by a gentle mix. Pipette 300 µL 1x Assay Diluent D into each tube. Use the stock standard solution to produce a dilution series (shown below). Mix each tube thoroughly before the next transfer. 1x Assay Diluent D serves as the zero standard (0 ng/ml). 200 µL 200 µL 200 µL 200 µL 200 µL Standard, Item C + 400 µL 200myl 200 80 32 12.8 5.12 2.05 0.819 0 ng/ml ng/ml ng/ml ng/ml ng/ml ng/ml ng/ml ng/ml 5. If the Wash Concentrate (20x) (Item B) contains visible crystals, warm to room temperature and mix gently until dissolved. Dilute 20 mL of Wash Buffer Concentrate into deionized or distilled water to yield 400 mL of 1x Wash Buffer. 6. Briefly spin the Detection Antibody vial (Item F) before use. Add 100 µL of 1x Assay Diluent B (Item E) into the vial to prepare a The Mouse CXCL15 ELISA Kit Protocol 4 detection antibody concentrate. Pipette up and down to mix gently (the concentrate can be stored at 4 °C for 5 days). The detection antibody concentrate should be diluted 80-fold with 1x Assay Diluent B and used in step 4 of Part VI Assay Procedure. 7. Briefly spin the HRP-Streptavidin concentrate vial (Item G) and pipette up and down to mix gently before use. HRP-Streptavidin concentrate should be diluted 800-fold with 1x Assay Diluent B (Item E). For example: Briefly spin the vial (Item G) and pipette up and down to mix gently . Add 15 µL of HRP-Streptavidin concentrate into a tube with 12 mL 1x Assay Diluent B to prepare a 800-fold diluted HRP-Streptavidin solution (don't store the diluted solution for next day use). Mix well.
    Procédure de l'essai
    1. Bring all reagents and samples to room temperature (18 - 25 °C) before use. It is recommended that all standards and samples be run at least in duplicate. 2. Add 100 µL of each standard (see Reagent Preparation step 2) and sample into appropriate wells. Cover well and incubate for 2.5 hours at room temperature or overnight at 4 °C with gentle shaking. 3. Discard 4. Add 100 µL of 1x prepared biotinylated antibody (Reagent Preparation step 6) to each well. Incubate for 1 hour at room temperature with gentle shaking. 5. Discard the solution. Repeat the wash as in step 3. 6. Add 100 µL of prepared Streptavidin solution (see Reagent Preparation step 7) to each well. Incubate for 45 minutes at room temperature with gentle shaking. 7. Discard the solution. Repeat the wash as in step 3. 8. Add 100 µL of TMB One-Step Substrate Reagent (Item H) to each well. Incubate for 30 minutes at room temperature in the dark with gentle shaking. 9. Add 50 µL of Stop Solution (Item I) to each well. Read at 450 nm immediately.
    Calcul des résultats

    Calculate the mean absorbance for each set of duplicate standards, controls and samples, and subtract the average zero standard optical density. Plot the standard curve on log-log graph paper or using Sigma plot software, with standard concentration on the x-axis and absorbance on the y-axis. Draw the best-fit straight line through the standard points.

    Précision du teste
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Restrictions
    For Research Use only
  • Conseil sur la manipulation
    Avoid repeated freeze-thaw cycles.
    Stock
    -20 °C
    Stockage commentaire
    The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.
    Date de péremption
    6 months
  • Antigène Voir toutes Chemokine (C-X-C Motif) Ligand 15 (CXCL15) Kits ELISA
    Chemokine (C-X-C Motif) Ligand 15 (CXCL15)
    Autre désignation
    CXCL15 (CXCL15 Produits)
    Synonymes
    Il8 Kit ELISA, Scyb15 Kit ELISA, lungkine Kit ELISA, weche Kit ELISA, chemokine (C-X-C motif) ligand 15 Kit ELISA, Cxcl15 Kit ELISA
    ID gène
    20309
    UniProt
    Q9WVL7
Vous êtes ici:
Support technique