Uric Acid/Uricase Assay Kit

BCA Fluorometric Plasma, Serum, Urine Quantitative
N° du produit ABIN2345042
  • Méthode de détection
    Fluorometric
    Application
    Biochemical Assay (BCA)
    Fonction
    The Uric Acid/Uricase Assay Kit is a sensitive quantitative fluorometric assay for measuring uric acid or uricase concentrations.
    Type d'échantillon
    Serum, Plasma, Urine
    Analytical Method
    Quantitative
    Sensibilité
    0.5 μM
    Attributs du produit
    Uric Acid/Uricase Assay Kit is a simple HTS-compatible assay for measuring uric acid concentrations in biological samples such as serum, plasma, and urine without any need for pretreatment. The kit has detection sensitivity limit of 0.5 μM of uric acid or 1 mU/mL uricase. Each kit provides sufficient reagents to perform up to 400 assays, including standard curve and unknown samples.
    Ingrédients
    1. Uric Acid Standard : One 100 mg tube of powder.
    2. Fluorescence Probe : One 200 μL amber tube of a 10 mM solution in DMSO.
    3. HRP : One 100 μL tube of 100 U/mL solution in glycerol.
    4. 10X Assay Buffer : One 25 mL bottle.

    Box 2 (shipped on blue ice packs)

    Matériel non inclus
    1. 1N NaOH and deionized water
    2. 100 mM Tris, pH 7.5
    3. 1X PBS for sample dilutions and controls as necessary
    4. 10 μL to 1000 μL adjustable single channel micropipettes with disposable tips
    5. 50 μL to 300 μL adjustable multichannel micropipette with disposable tips
    6. Standard 96-well fluorescence black microtiter plates
    7. Multichannel micropipette reservoir
    8. Fluorescence microplate reader capable of reading excitation in the 530-570 nm range and emission in the 590-600 nm range.
  • Indications d'application
    Optimal working dilution should be determined by the investigator.
    Commentaires

    • Detection sensitivity limit of 0.5 μM of uric acid or 1 mU/mL uricase
    • Measures uric acid concentrations in biological samples such as serum, plasma, and urine without any need for pretreatment

    Protocole
    Uric acid reacts with water and oxygen in the presence of the enzyme uricase to produce allantoin and H2O2. In the presence of HRP, a Fluorescence Probe reacts with H2O2 in a 1:1 stoichiometry to produce a highly fluorescent product. This fluorescent product can be easily read by a fluorescence microplate reader with an excitation of 530-560 nm and an emission of 590 nm. Fluorescence values are proportional to the uric acid or uricase levels within the samples, depending on which compound is being measured. The uric acid or uricase content in unknown samples is determined by comparison with its respective standard curve .
    Préparation des réactifs

    Note: All reagents must be brought to room temperature prior to use.

    • 1X Assay Buffer: Warm the 10X Assay Buffer to room temperature prior to using. Prepare a 1X Assay Buffer by diluting the 10X Assay Buffer with deionized water. Add 25 mL 10X Assay Buffer to 225 mL deionized water for 250 mL total. Mix to homogeneity. Store the 1X Assay Buffer at 4 °C up to 12 months.
    • Uric Acid Working Reagent (Uric Acid Assay): If measuring uric acid, prepare a Uric Acid Working Reagent by diluting the Fluorescence Probe 1:100, HRP 1:250, and Uricase 1:250 in 1X 4 Assay Buffer (e.g. For 100 assays, combine 50 μL of Fluorescence Probe, 20 μL HRP, and 20 μL Uricase with 1X Assay Buffer to a 5 mL total volume). Mix thoroughly and protect the solution from light. For best results, use the Uric Acid Working Reagent within 30 minutes of preparation. Prepare only enough for immediate use. Do not store the Working Reagent solution.
    • Uricase Working Reagent (Uricase Assay): Prior to measuring uricase activity, weigh out the Uric Acid Standard powder for a 10 mg/mL solution in 1N NaOH. This 10 mg/mL is equivalent to a concentration of 60 mM. Once dissolved, dilute the 60 mM uric acid solution to a concentration of 10 mM in 100 mM Tris, pH 7.5. Vortex thoroughly. Next, prepare the Uricase Working Reagent by diluting the Fluorescence Probe 1:100, HRP 1:250, and uric acid solution 1:10 in 1X Assay Buffer (e.g. for 100 assays, combine 50 μL of Fluorescence Probe, 20 μL HRP, and 500 μL Uric Acid with 1X Assay Buffer to a 5 mL total volume). Mix thoroughly and protect the solution from light. For best results, use the Uricase Working Reagent within 30 minutes of preparation. Prepare only enough for immediate use. Do not store the Working Reagent solution. Note: If uric acid solution has visible precipitation, or does not readily go into solution, warm the solution at 37 °C and vortex thoroughly to resuspend and dissolve.

    Préparation de l'échantillon
    • Cell Culture Supernatant: To remove insoluble particles, centrifuge at 10,000 rpm for 5 min. The supernatant can be assayed directly or diluted as necessary. Prepare the standard curve in the same non-conditioned media. Note: Maintain pH between 7 and 8 for optimal working conditions as the Fluorescent Probe is unstable at high pH (>8.5).
    • Cell Lysate: Resuspend cells at 1-2 x 106 cells/mL in 1X Assay Buffer or PBS. Homogenize or sonicate the cells on ice. Centrifuge to remove debris. Cell lysates can be assayed undiluted or titrated as necessary.
    • Serum: Collect blood without using an anticoagulant and allow to clot for 30 minutes at 25 °C. Centrifuge at 2000 x g and 4 °C for 15 minutes. Remove the serum layer and store on ice. Avoid disturbing the white buffy layer. Aliquot samples for testing and store at -80 °C. Perform dilutions in 1X Assay Buffer or PBS.
    • Plasma: Collect blood with heparin or citrate and centrifuge at 500-1000 x g and 4 °C for 10 minutes. Remove the plasma layer and store on ice. Avoid disturbing the white buffy layer. Aliquot samples for testing and store at -80 °C. Perform dilutions in 1X Assay Buffer or PBS.
    • Urine: To remove insoluble particles, centrifuge at 10,000 rpm for 5 min. The supernatant can be assayed directly or diluted as necessary. Dilute in 1X Assay Buffer or PBS. Aliquot samples for testing and store at -80 °C. Notes:
    • All samples should be assayed immediately or stored at -80 °C for up to 1-2 months. Run proper controls as necessary. Optimal dilution conditions for samples must be determined by the investigator. Always run a standard curve with samples.
    • Samples with NADH concentrations above 10 μM and glutathione concentrations above 50 μM will oxidize the probe and could result in erroneous readings. To minimize this interference, it is recommended that superoxide dismutase (SOD) be added to the reaction at a final concentration of 40 U/mL (Votyakova and Reynolds, Ref. 2). 5
    • Avoid samples containing DTT or β-mercaptoethanol since the probe is not stable in the presense of thiols (above 10 μM).
    • Uric acid values from urine can be normalized to creatinine levels.
    Procédure de l'essai

    I. Uric Acid

    1. Prepare and mix all reagents thoroughly before use. Each sample, including unknowns and standards, should be assayed in duplicate or triplicate.
    2. Add 50 μL of each sample (uric acid standards, hydrogen peroxide controls or unknowns) into an individual microtiter plate well.
    3. Add 50 μL of Uric Acid Working Reagent to each well. Mix the well contents thoroughly and incubate for 20 minutes at 37 °C and protected from light. Note: This assay is continuous (not terminated) and therefore may be measured at multiple time points to follow the kinetics of the reactions.
    4. Read the plate with a fluorescence microplate reader equipped for excitation in the 530-570 nm range and for emission in the 590-600 nm range.
    5. Calculate the concentration of uric acid within samples by comparing the sample RFUs to the uric acid standard curve. Subtract the value from the zero uric acid control well.

    II. Uricase

    1. Prepare and mix all reagents thoroughly before use. Each sample, including unknowns and standards, should be assayed in duplicate or triplicate.
    2. Add 50 μL of each sample (uricase standards, hydrogen peroxide controls or unknowns) into an individual microtiter plate well.
    3. Add 50 μL of Uricase Working Reagent to each well. Mix the well contents thoroughly and incubate for 60 minutes at 37 °C and protected from light. Note: This assay is continuous (not terminated) and therefore may be measured at multiple time points to follow the kinetics of the reactions.
    4. Read the plate with a fluorescence microplate reader equipped for excitation in the 530-570 nm range and for emission in the 590-600 nm range.
    5. Calculate the concentration of uricase within samples by comparing the sample RFUs to the uricase standard curve. Subtract the value from the zero uricase control well. 7

    Restrictions
    For Research Use only
  • Conseil sur la manipulation
    Avoid multiple freeze/thaw cycles.
    Stock
    4 °C/-20 °C
    Stockage commentaire
    Upon receipt, aliquot and store the Fluorescence Probe, HRP, and Uricase at -20°C. The Fluorescence Probe is light sensitive and must be stored accordingly. Avoid multiple freeze/thaw cycles. Store the remaining kit components at room temperature.
  • Shani, Vinker, Dinour, Leiba, Twig, Holtzman, Leiba: "High Normal Uric Acid Levels Are Associated with an Increased Risk of Diabetes in Lean, Normoglycemic Healthy Women." dans: The Journal of clinical endocrinology and metabolism, Vol. 101, Issue 10, pp. 3772-3778, (2016) (PubMed).

    Moriya, Satoh: "Teneligliptin Decreases Uric Acid Levels by Reducing Xanthine Dehydrogenase Expression in White Adipose Tissue of Male Wistar Rats." dans: Journal of diabetes research, Vol. 2016, pp. 3201534, (2016) (PubMed).

    Leiba, Vinker, Dinour, Holtzman, Shani: "Uric acid levels within the normal range predict increased risk of hypertension: a cohort study." dans: Journal of the American Society of Hypertension : JASH, Vol. 9, Issue 8, pp. 600-9, (2015) (PubMed).

  • Sujet
    For humans and higher primates, uric acid is the final oxidation end product of purine nucleotide metabolism. The enzyme xanthine oxidase makes uric acid from xanthine and hypoxanthine, which are derived from purines. Although most animals can metabolize uric acid to the easily excreted product allantoin, humans lack the necessary enzyme, urate oxidase (uricase), due to two nonsense mutations in the uricase gene. Uric acid is released in hypoxic conditions and is usually excreted in the urine via glomerular filtration. Approximately 70 % of daily uric acid disposal occurs via the kidneys. Like ascorbic acid, uric acid is a strong reducing agent (electron donor) and a potent antioxidant. In humans, over half of the antioxidant capacity of blood plasma is derived from uric acid. High levels of uric acid have been linked to impaired renal function, polycythemia, leukemia, as well as consumption of foods high in nucleoproteins. Genetic and acquired influences, such as obesity and alcohol consumption, influence uric acid concentrations. Hyperuricemia induces or accelerates the development of gout, kidney stones, hypertension, metabolic syndrome, and renal and cardiovascular disease. Within 5- 25 % of humans, impaired renal (kidney) excretion leads to hyperuricemia. Gout is an inflammatory condition that results from uric acid deposits within the body joints. Exercise induced acute renal failure or impairment is a major complication related to hypouricemia.
Vous êtes ici:
Support technique