N° du produit ABIN2851230
  • Antigène Voir toutes IARS Kits ELISA
    IARS (Isoleucyl-tRNA Synthetase (IARS))
    Reactivité
    • 3
    • 2
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    0.312 ng/mL - 20 ng/mL
    Seuil minimal de détection
    0.312 ng/mL
    Application
    ELISA
    Fonction
    The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of IARS in human serum, plasma, tissue homogenates and other biological fluids.
    Type d'échantillon
    Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificité
    This assay has high sensitivity and excellent specificity for detection of this index.
    Réactivité croisée (Details)
    No significant cross-reactivity or interference between this index and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross- reactivity detection between this index and all the analogues, therefore, cross reaction may still exist.
    Sensibilité
    0.108 ng/mL
    Ingrédients
    • Pre-coated, ready to use 96-well strip plate
    • Standard (freeze dried)
    • Standard Diluent
    • Detection Reagent A
    • Detection Reagent B
    • Assay Diluent A
    • Assay Diluent B
    • TMB
    • Stop Solution
    • Wash Buffer (30X)
    • Plate sealer for 96 wells
    • Instruction manual
    Matériel non inclus
    1. Microplate reader with 450 ± 10nm filter.
    2. Precision single or multi-channel pipettes and disposable tips.
    3. Eppendorf Tubes for diluting samples.
    4. Deionized or distilled water.
    5. Absorbent paper for blotting the microtiter plate.
    6. Container for Wash Solution.
    Featured
    Discover our best selling IARS Kit ELISA
    Top Product
    Discover our top product IARS Kit ELISA
  • Volume d'échantillon
    100 μL
    Durée du test
    1 - 4.5 h
    Plaque
    Pre-coated
    Protocole
    1. Prepare all reagents, samples and standards
    2. Add 100µL standard or sample to each well. Incubate 2 hours at 37°C
    3. Aspirate and add 100µL prepared Detection Reagent A. Incubate 1 hour at 37°C
    4. Aspirate and wash 3 times
    5. Add 100µL prepared Detection Reagent B. Incubate 1 hour at 37°C
    6. Aspirate and wash 5 times
    7. Add 90µL Substrate Solution. Incubate 15-25 minutes at 37°C
    8. Add 50µL Stop Solution. Read at 450nm immediately.
    Procédure de l'essai

    The microtiter plate provided in this kit has been pre-coated with an antibody specific to the index. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody preparation specific to the index. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain the index, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of the index in the samples is then determined by comparing the O.D. of the samples to the standard curve.

    Précision du teste
    • Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level the index were tested 20 times on one plate, respectively.
    • Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level the index were tested on 3 different plates, 8 replicates in each plate.
    • CV(%) = SD/meanX100
    • Intra-assay: CV<10%
    • Inter-assay: CV<12%
    Restrictions
    For Research Use only
  • Précaution d'utilisation
    The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
    Conseil sur la manipulation
    The stability of ELISA kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage conditions. Note: To minimize unnecessary influences on the performance, operation procedures and lab conditions, especially room temperature, air humidity and incubator temperatures should be strictly regulated. It is also strongly suggested that the whole assay is performed by the same experimenter from the beginning to the end.
    Stock
    4 °C,-20 °C
    Stockage commentaire
    The Assay Plate, Standard, Detection Reagent A and Detection Reagent B should be stored at -20°C upon being received. After receiving the kit , Substrate should be always stored at 4°C.Other reagents are kept according to the labels on vials. But for long term storage, please keep the whole kit at -20°C. The unused strips should be kept in a sealed bag with the desiccant provided to minimize exposure to damp air. The test kit may be used throughout the expiration date of the kit (six months from the date of manufacture). Opened test kits will remain stable until the expiring date shown, provided it is stored as prescribed above.
    Date de péremption
    12 months
  • Antigène Voir toutes IARS Kits ELISA
    IARS (Isoleucyl-tRNA Synthetase (IARS))
    Autre désignation
    IARS (IARS Produits)
    Synonymes
    fi46h05 Kit ELISA, zgc:63790 Kit ELISA, wu:fi46h05 Kit ELISA, K19E20.18 Kit ELISA, K19E20_18 Kit ELISA, ovule abortion 2 Kit ELISA, ECK0027 Kit ELISA, ilvS Kit ELISA, JW0024 Kit ELISA, An08g06770 Kit ELISA, AO090012000505 Kit ELISA, 2510016L12Rik Kit ELISA, AI327140 Kit ELISA, AU044614 Kit ELISA, E430001P04Rik Kit ELISA, ILRS Kit ELISA, Iarsl Kit ELISA, IARS1 Kit ELISA, ILERS Kit ELISA, IRS Kit ELISA, PRO0785 Kit ELISA, isoleucyl-tRNA synthetase Kit ELISA, tRNA synthetase class I (I, L, M and V) family protein Kit ELISA, isoleucine--tRNA ligase Kit ELISA, isoleucyl-tRNA synthetase, cytoplasmic Kit ELISA, isoleucine-tRNA synthetase Kit ELISA, iars Kit ELISA, IARS Kit ELISA, OVA2 Kit ELISA, ileS Kit ELISA, MBAR_RS19160 Kit ELISA, Rmag_0340 Kit ELISA, ANI_1_964074 Kit ELISA, CHLREDRAFT_106327 Kit ELISA, EDI_049880 Kit ELISA, OE_RS08520 Kit ELISA, AOR_1_1912194 Kit ELISA, Iars Kit ELISA
    Sujet
    Alternative name: IARS1, ILRS, OJ, IleRS, IRS, Isoleucine tRNA Ligase 1,Cytoplasmic
    ID gène
    3376
    UniProt
    P41252
Vous êtes ici:
Support technique