Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

SULF2 Kit ELISA

SULF2 Reactivité: Humain Colorimetric Competition ELISA 0.312-20 ng/mL Cell Culture Supernatant, Plasma, Serum
N° du produit ABIN454343
  • Antigène Voir toutes SULF2 Kits ELISA
    SULF2 (Sulfatase 2 (SULF2))
    Reactivité
    • 3
    • 2
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Competition ELISA
    Gamme de detection
    0.312-20 ng/mL
    Seuil minimal de détection
    0.312 ng/mL
    Application
    ELISA
    Fonction
    This immunoassay kit allows for the use in vitro quantitative determination of human anti-insulin receptor antibody, AIRA concentrations in cell culture supernates, serum, plasma and other biological fluids.
    Type d'échantillon
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Quantitative
    Specificité
    This assay recognizes recombinant and natural human AIRA.
    Réactivité croisée (Details)
    No significant cross-reactivity or interference was observed.
    Sensibilité
    < 0.39 U/mL
    The sensitivity of this assay, or Lower Limit of Detection (LLD) was defined as the lowest detectable concentration that could be differentiated from zero.
    Attributs du produit
    Homo sapiens,Human,Extracellular sulfatase Sulf-2,hSulf-2,SULF2,KIAA1247,UNQ559/PRO1120,3.1.6.-
    Ingrédients
    Reagent (Quantity): Assay plate (1), Standard (2), Sample Diluent (1x20ml), Assay Diluent A (1x10ml), Assay DiluentB 1 x 10ml Detection Reagent A (1x120µl), Detection Reagent B (1x120µl), Wash Buffer(25 x concentrate) (1x30ml), Substrate (1x10ml), Stop Solution (1x10ml)
    Featured
    Discover our best selling SULF2 Kit ELISA
    Top Product
    Discover our top product SULF2 Kit ELISA
  • Volume d'échantillon
    100 μL
    Plaque
    Pre-coated
    Protocole
    The microtiter plate provided in this kit has been pre-coated with an antigen of IR. Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated polyclonal antibody preparation specific for IR and Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then a TMB (3,3'5, 5' tetramethyl-benzidine) substrate solution is added to each well. Only those wells that contain AIRA, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of a sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450 nm ± 2 nm. The concentration of AIRA in the samples is then determined by comparing the O.D. of the samples to the standard curve.
    Préparation des réactifs

    Bring all reagents to room temperature before use. Wash Buffer - If crystals have formed in the concentrate, warm to room temperature and mix gently until the crystals have completely dissolved. Dilute 30 mL of Wash Buffer Concentrate into deionized or distilled water to prepare 750 mL of Wash Buffer. Standard - Reconstitute the Standard with 1.0 mL of Sample Diluent. This reconstitution produces a stock solution of 100 U/mL. Allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making serial dilutions. The undiluted standard serves as the high standard (100 U/mL). The Sample Diluent serves as the zero standard (0 U/mL). Detection Reagent A and B - Dilute to the working concentration specified on the vial label using Assay Diluent A and B (1:100), respectively.

    Prélèvement de l'échantillon
    Serum - Use a serum separator tube (SST) and allow samples to clot for 30 minutes before 2 centrifugation for 15 minutes at approximately 1000 x g. Remove serum and assay immediately or aliquot and store samples at -20 °C or -80 °C. Plasma - Collect plasma using EDTA or heparin as an anticoagulant. Centrifuge samples for 15 minutes at 1000 x g at 2 - 8 °C within 30 minutes of collection. Store samples at -20 °C or -80 °C. Avoid repeated freeze-thaw cycles. Cell culture supernates and other biological fluids - Remove particulates by centrifugation and assay immediately or aliquot and store samples at -20 °C or -80 °C. Avoid repeated freeze-thaw cycles. Note: Serum, plasma, and cell culture supernatant samples to be used within 7 days may be stored at 2-8C, otherwise samples must stored at -20 °C (≤ 3 months) or -80 °C (≤ 6 months) to avoid loss of bioactivity and contamination. Avoid freeze-thaw cycles. When performing the assay slowly bring samples to room temperature. It is recommended that all samples be assayed in duplicate.
    Procédure de l'essai

    Allow all reagents to reach room temperature. All the reagents should be mixed thoroughly by gently swirling before pipetting. Avoid foaming. Arrange and label required number of strips. Prepare all reagents, working standards and samples as directed in the previous sections. 3
    1. Add 100 uL of Standard, Blank, or Sample per well. Cover with the adhesive strip. Incubate for 2 hours at 37 °C.
    2. Remove the liquid of each well, don’t wash.
    3. Add 100 uL of Detection Reagent A working solution to each well. Incubate for 1 hour at 37°C. Detection Reagent A working solution may appear cloudy. Warm to room temperature and mix gently until solution appears uniform.
    4. Aspirate each well and wash, repeating the process three times for a total of three washes. Wash by filling each well with Wash Buffer (350 uL) using a squirt bottle, multi-channel pipette, manifold dispenser or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
    5. Add 100 uL of Detection Reagent B working solution to each well. Cover with a new adhesive strip.Incubate for 1 hours at 37 °C.
    6. Repeat the aspiration/wash as in step
    5. 7. Add 90 uL of Substrate Solution to each well. Incubate within 30 minutes at 37°C. Protect from light.
    8. Add 50 uL of Stop Solution to each well. If color change does not appear uniform, gently tap the plate to ensure thorough mixing.
    9. Determine the optical density of each well at once, using a microplate reader set to 450 nm.
    Important Note:
    1. Please carefully reconstitute Standards or working Detection Reagent A and B according to the instruction, and avoid foaming and mix gently until the crystals have completely dissolved. The reconstituted Standards can be used only once.
    2. The wash procedure is critical. Insufficient washing will result in poor precision and falsely elevated absorbance readings.
    3. It is recommended that no more than 32 wells be used for each assay run if manual pipetting is used since pipetting of all standards, specimens and controls should be completed within 5 minutes. A full plate of 96 wells may be used if automated pipetting is available.
    4. Duplication of all standards and specimens, although not required, is recommended.
    5. When mixing or reconstituting protein solutions, always avoid foaming. 4
    6. To avoid cross-contamination, change pipette tips between additions of each standard level, between sample additions, and between reagent additions. Also, use separate reservoirs for each reagent.
    7. To ensure accurate results, proper adhesion of plate sealers during incubation steps is necessary.
    8. Do not substitute reagents from one kit lot to another. Use only the reagents supplied by manufacturer.

    Calcul des résultats

    Average the duplicate readings for each standard, control, and sample and subtract the average zero standard optical density. Create a standard curve by reducing the data using computer software capable of generating a four parameter logistic (4-PL) curve-fit. As an alternative, construct a standard curve by plotting the mean absorbance for each standard on the y-axis against the concentration on the x-axis and draw a best fit curve through the points on the graph. The data may be linearized by plotting the log of the AIRA concentrations versus the log of the O.D. and the best fit line can be determined by regression analysis. This procedure will produce an adequate but less precise fit of the data. If samples have been diluted, the concentration read from the standard curve must be multiplied by the dilution factor.

    Restrictions
    For Research Use only
  • Conseil sur la manipulation
    1. The kit should not be used beyond the expiration date on the kit label.
    2. Do not mix or substitute reagents with those from other lots or sources.
    3. If samples generate values higher than the highest standard, further dilute the samples with the Assay Diluent and repeat the assay. Any variation in standard diluent, operator, pipetting technique, washing technique,incubation time or temperature, and kit age can cause variation in binding.
    4. This assay is designed to eliminate interference by soluble receptors, ligands, binding proteins, and other factors present in biological samples. Until all factors have been tested in the Immunoassay, the possibility of interference cannot be excluded.
    Stock
    4 °C/-20 °C
    Stockage commentaire
    The Standard, Detection Reagent A, Detection Reagent B and the 96-well strip plate should be stored at -20 °C upon being received. The other reagents can be stored at 4 °C.
  • Antigène Voir toutes SULF2 Kits ELISA
    SULF2 (Sulfatase 2 (SULF2))
    Autre désignation
    SULF2 (SULF2 Produits)
    Synonymes
    Sulf1 Kit ELISA, zgc:55612 Kit ELISA, SULF2 Kit ELISA, si:dkeyp-84g9.1 Kit ELISA, wu:fb48e04 Kit ELISA, HSULF-2 Kit ELISA, xtsulf2 Kit ELISA, 2010004N24Rik Kit ELISA, AU020235 Kit ELISA, MSulf-2 Kit ELISA, mKIAA1247 Kit ELISA, sulfatase 2a Kit ELISA, sulfatase 2 Kit ELISA, extracellular sulfatase Sulf-2 Kit ELISA, sulfatase 2b Kit ELISA, sulfatase 2 S homeolog Kit ELISA, sulf2a Kit ELISA, SULF2 Kit ELISA, LOC100540921 Kit ELISA, sulf2 Kit ELISA, sulf2b Kit ELISA, sulf2.S Kit ELISA, Sulf2 Kit ELISA
    Classe de substances
    Antibody
Vous êtes ici:
Support technique