- Antigène
- Androsterone (ADT)
- Reactivité
- Différentes espèces
- Méthode de détection
- Colorimetric
- Type de méthode
- Competition ELISA
- Gamme de detection
- 352 pg/mL - 90000 pg/mL
- Seuil minimal de détection
- 352 pg/mL
- Application
- ELISA
- Type d'échantillon
- Plasma, Serum
- Analytical Method
- Quantitative
- Specificité
- This assay has high sensitivity and excellent specificity for detection of Androsterone (ADT). No significant cross-reactivity or interference between Androsterone (ADT) and analogues was observed.
- Sensibilité
- 144 pg/mL
-
-
- Commentaires
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Durée du test
- 2 h
- Plaque
- Pre-coated
- Protocole
- This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Androsterone (ADT) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Androsterone (ADT) and unlabeled Androsterone (ADT) (Standards or samples) with the pre-coated antibody specific to Androsterone (ADT). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Androsterone (ADT) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Androsterone (ADT) in the sample.
- Précision du teste
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Androsterone (ADT) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Androsterone (ADT) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Conseil sur la manipulation
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Stock
- 4 °C,-20 °C
- Stockage commentaire
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Date de péremption
- 4-8 months
-
- Antigène
- Androsterone (ADT)
- Autre désignation
- Androsterone
- Classe de substances
- Hormone
- Sujet
-
Gene Name: Androsterone
Gene Aliases: 17-Ketosteroid, 17-KS, 3a-Hydroxy-17-Androstanone
-