Estrone Kit CLIA
-
- Antigène Voir toutes Estrone Kits CLIA
- Estrone
-
Reactivité
- Différentes espèces
- Méthode de détection
- Chemiluminescent
- Type de méthode
- Competition ELISA
- Gamme de detection
- 23.44 pg/mL - 6000 pg/mL
- Seuil minimal de détection
- 23.44 pg/mL
- Application
- ELISA
- Type d'échantillon
- Plasma, Serum
- Analytical Method
- Quantitative
- Specificité
- This assay has high sensitivity and excellent specificity for detection of Estrone (E1). No significant cross-reactivity or interference between Estrone (E1) and analogues was observed.
- Sensibilité
- 7.96 pg/mL
- Featured
- Discover our best selling Estrone Kit ELISA
- Top Product
- Discover our top product Estrone Kit ELISA
-
-
- Commentaires
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Durée du test
- 2 h
- Plaque
- Pre-coated
- Protocole
- The microplate provided in this kit has been pre-coated with a monoclonal antibody specific to Estrone (E1). A competitive inhibition reaction is launched between biotin labeled Estrone (E1) and unlabeled Estrone (E1) (Standards or samples) with the pre-coated antibody specific to Estrone (E1). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Estrone (E1) in the sample. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is reverse proportional to the Estrone (E1) level in the sample or standard.
- Précision du teste
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Estrone (E1) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Estrone (E1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Conseil sur la manipulation
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Stock
- 4 °C,-20 °C
- Stockage commentaire
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Date de péremption
- 4-8 months
-
- Antigène Voir toutes Estrone Kits CLIA
- Estrone
- Abstract
- Estrone Produits
- Classe de substances
- Amino Acid
- Sujet
-
Gene Name: Estrone
Gene Aliases: Oestrone
-