FGF12 Kit CLIA
-
- Antigène Voir toutes FGF12 Kits CLIA
- FGF12 (Fibroblast Growth Factor 12 (FGF12))
-
Reactivité
- Souris
- Méthode de détection
- Chemiluminescent
- Type de méthode
- Sandwich ELISA
- Gamme de detection
- 15.62 pg/mL - 1000 pg/mL
- Seuil minimal de détection
- 15.62 pg/mL
- Application
- ELISA
- Type d'échantillon
- Plasma, Serum
- Analytical Method
- Quantitative
- Specificité
- This assay has high sensitivity and excellent specificity for detection of Fibroblast Growth Factor 12 (FGF12). No significant cross-reactivity or interference between Fibroblast Growth Factor 12 (FGF12) and analogues was observed.
- Sensibilité
- 0.61 pg/mL
- Top Product
- Discover our top product FGF12 Kit ELISA
-
-
- Commentaires
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Durée du test
- 2 - 3 h
- Plaque
- Pre-coated
- Protocole
- The microplate provided in this kit has been pre-coated with an antibody specific to Fibroblast Growth Factor 12 (FGF12). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Fibroblast Growth Factor 12 (FGF12). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Fibroblast Growth Factor 12 (FGF12) level in the sample or standard.,
- Précision du teste
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fibroblast Growth Factor 12 (FGF12) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fibroblast Growth Factor 12 (FGF12) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Conseil sur la manipulation
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Stock
- 4 °C,-20 °C
- Stockage commentaire
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Date de péremption
- 4-8 months
-
- Antigène Voir toutes FGF12 Kits CLIA
- FGF12 (Fibroblast Growth Factor 12 (FGF12))
- Autre désignation
- Fibroblast Growth Factor 12 (FGF12 Produits)
- Synonymes
- FHF1 Kit CLIA, FHF-1 Kit CLIA, MGC84150 Kit CLIA, FGF12 Kit CLIA, fgf12 Kit CLIA, zgc:153104 Kit CLIA, fhf1 Kit CLIA, fgf12b Kit CLIA, DKFZp459P139 Kit CLIA, FGF12B Kit CLIA, AV114868 Kit CLIA, FGF-12 Kit CLIA, Fhf1 Kit CLIA, Fhf1b Kit CLIA, fibroblast growth factor 12 Kit CLIA, fibroblast growth factor 12 S homeolog Kit CLIA, fibroblast growth factor 12a Kit CLIA, FGF12 Kit CLIA, fgf12.S Kit CLIA, fgf12a Kit CLIA, fgf12 Kit CLIA, Fgf12 Kit CLIA
- Sujet
-
Gene Name: Fibroblast Growth Factor 12
Gene Aliases: FGF12B, FHF1, Fibroblast Growth Factor Homologous Factor 1, Myocyte-Activating Factor
- Pathways
- Negative Regulation of Transporter Activity
-