Fusion (FUS) Kit ELISA
-
- Antigène
- Fusion (FUS)
-
Reactivité
- Souris
- Méthode de détection
- Colorimetric
- Type de méthode
- Sandwich ELISA
- Gamme de detection
- 0.156 ng/mL - 10 ng/mL
- Seuil minimal de détection
- 0.156 ng/mL
- Application
- ELISA
- Type d'échantillon
- Tissue Homogenate
- Analytical Method
- Quantitative
- Specificité
- This assay has high sensitivity and excellent specificity for detection of Fusion (FUS). No significant cross-reactivity or interference between Fusion (FUS) and analogues was observed.
- Sensibilité
- 0.058 ng/mL
- Featured
- Discover our best selling Kit ELISA
-
-
- Commentaires
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Durée du test
- 3 h
- Plaque
- Pre-coated
- Protocole
- The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Fusion (FUS). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Fusion (FUS). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Fusion (FUS), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Fusion (FUS) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
- Précision du teste
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Fusion (FUS) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Fusion (FUS) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Conseil sur la manipulation
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Stock
- 4 °C,-20 °C
- Stockage commentaire
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Date de péremption
- 4-8 months
-
- Antigène
- Fusion (FUS)
- Autre désignation
- Fusion
- Synonymes
- ALS6 Kit ELISA, ETM4 Kit ELISA, FUS1 Kit ELISA, HNRNPP2 Kit ELISA, POMP75 Kit ELISA, TLS Kit ELISA, D430004D17Rik Kit ELISA, D930039C12Rik Kit ELISA, Fus1 Kit ELISA, Tls Kit ELISA, FUS RNA binding protein Kit ELISA, fused in sarcoma Kit ELISA, FUS Kit ELISA, Fus Kit ELISA
- Sujet
-
Gene Name: Fusion
Gene Aliases: CHOP, ALS6, TLS, hnRNP-P2, Amyotrophic Lateral Sclerosis 6, Heterogeneous Nuclear Ribonucleoprotein P2, 75 kDa DNA-pairing protein, Translocated in liposarcoma protein
- ID gène
- 233908
- UniProt
- P56959
-