GLYT1 Kit ELISA
-
- Antigène Voir toutes GLYT1 Kits ELISA
- GLYT1 (Glycine Transporter 1 (GLYT1))
- Reactivité
- Humain
- Méthode de détection
- Colorimetric
- Type de méthode
- Sandwich ELISA
- Gamme de detection
- 0.312 ng/mL - 20 ng/mL
- Seuil minimal de détection
- 0.312 ng/mL
- Application
- ELISA
- Type d'échantillon
- Tissue Homogenate
- Analytical Method
- Quantitative
- Specificité
- This assay has high sensitivity and excellent specificity for detection of Glycine Transporter 1 (GLYT1). No significant cross-reactivity or interference between Glycine Transporter 1 (GLYT1) and analogues was observed.
- Sensibilité
- 0.134 ng/mL
- Featured
- Discover our best selling GLYT1 Kit ELISA
- Top Product
- Discover our top product GLYT1 Kit ELISA
-
-
- Commentaires
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Durée du test
- 3 h
- Plaque
- Pre-coated
- Protocole
- The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Glycine Transporter 1 (GLYT1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Glycine Transporter 1 (GLYT1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Glycine Transporter 1 (GLYT1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Glycine Transporter 1 (GLYT1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
- Précision du teste
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Glycine Transporter 1 (GLYT1) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Glycine Transporter 1 (GLYT1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Conseil sur la manipulation
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Stock
- 4 °C,-20 °C
- Stockage commentaire
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Date de péremption
- 4-8 months
-
- Antigène Voir toutes GLYT1 Kits ELISA
- GLYT1 (Glycine Transporter 1 (GLYT1))
- Autre désignation
- Glycine Transporter 1 (GLYT1 Produits)
- Synonymes
- GLYT1 Kit ELISA, Glyt-1 Kit ELISA, Glyt1 Kit ELISA, GLYT-1 Kit ELISA, GLYT-1b Kit ELISA, glyt1 Kit ELISA, slc6a9 Kit ELISA, glyT-1 Kit ELISA, glyT1 Kit ELISA, solute carrier family 6 member 9 Kit ELISA, solute carrier family 6 (neurotransmitter transporter, glycine), member 9 Kit ELISA, glycine transporter 1 Kit ELISA, SLC6A9 Kit ELISA, Slc6a9 Kit ELISA, glyt1 Kit ELISA, slc6a9 Kit ELISA
- Sujet
-
Gene Name: Glycine Transporter 1
Gene Aliases: SLC6A9, Solute Carrier Family 6 Member 9,Neurotransmitter Transporter,Glycine, Sodium And Chloride Dependent Glycine Transporter 1
-