Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

IL28B Kit CLIA

Kit ELISA Humain IL28B, test Chemiluminescent pour la quantification de Humain IL28B.
N° du produit ABIN5655935

Aperçu rapide pour IL28B Kit CLIA (ABIN5655935)

Antigène

Voir toutes IL28B Kits CLIA
IL28B (Interleukin 28B (Interferon, lambda 3) (IL28B))

Reactivité

  • 4
  • 1
  • 1
Humain

Méthode de détection

Chemiluminescent

Type de méthode

Sandwich ELISA

Gamme de detection

15.62 pg/mL - 1000 pg/mL

Application

ELISA

Type d'échantillon

Plasma, Serum
  • Seuil minimal de détection

    15.62 pg/mL

    Analytical Method

    Quantitative

    Specificité

    This assay has high sensitivity and excellent specificity for detection of Interleukin 28B (IL28B). No significant cross-reactivity or interference between Interleukin 28B (IL28B) and analogues was observed.

    Sensibilité

    0.5 pg/mL
  • Commentaires

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Durée du test

    2 - 3 h

    Plaque

    Pre-coated

    Protocole

    The microplate provided in this kit has been pre-coated with an antibody specific to Interleukin 28B (IL28B). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Interleukin 28B (IL28B). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Interleukin 28B (IL28B) level in the sample or standard.,

    Précision du teste

    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Interleukin 28B (IL28B) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Interleukin 28B (IL28B) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%

    Restrictions

    For Research Use only
  • Conseil sur la manipulation

    Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.

    Stock

    4 °C,-20 °C

    Stockage commentaire

    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.

    Date de péremption

    4-8 months
  • Antigène Voir toutes IL28B Kits CLIA

    IL28B (Interleukin 28B (Interferon, lambda 3) (IL28B))

    Autre désignation

    Interleukin 28B

    Sujet

    Gene Name: Interleukin 28B

    Gene Aliases: IFNL3, Interferon,Lambda 3, Cytokine Zcyto22