Leukotriene A4 Kit ELISA
-
- Antigène Tous les produits Leukotriene A4 (LTA4)
- Leukotriene A4 (LTA4)
- Reactivité
- Différentes espèces
- Méthode de détection
- Colorimetric
- Type de méthode
- Competition ELISA
- Gamme de detection
- 123.5 pg/mL - 10000 pg/mL
- Seuil minimal de détection
- 123.5 pg/mL
- Application
- ELISA
- Type d'échantillon
- Cell Culture Supernatant, Plasma, Serum, Tissue Homogenate
- Analytical Method
- Quantitative
- Specificité
- This assay has high sensitivity and excellent specificity for detection of Leukotriene A4 (LTA4). No significant cross-reactivity or interference between Leukotriene A4 (LTA4) and analogues was observed.
- Sensibilité
- 46.3 pg/mL
- Featured
- Discover our best selling LTA4 Kit ELISA
-
-
- Commentaires
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Durée du test
- 2 h
- Plaque
- Pre-coated
- Protocole
- This assay employs the competitive inhibition enzyme immunoassay technique. A monoclonal antibody specific to Leukotriene A4 (LTA4) has been pre-coated onto a microplate. A competitive inhibition reaction is launched between biotin labeled Leukotriene A4 (LTA4) and unlabeled Leukotriene A4 (LTA4) (Standards or samples) with the pre-coated antibody specific to Leukotriene A4 (LTA4). After incubation the unbound conjugate is washed off. Next, avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. The amount of bound HRP conjugate is reverse proportional to the concentration of Leukotriene A4 (LTA4) in the sample. After addition of the substrate solution, the intensity of color developed is reverse proportional to the concentration of Leukotriene A4 (LTA4) in the sample.
- Précision du teste
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Leukotriene A4 (LTA4) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Leukotriene A4 (LTA4) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Conseil sur la manipulation
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Stock
- 4 °C,-20 °C
- Stockage commentaire
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Date de péremption
- 4-8 months
-
- Antigène Tous les produits Leukotriene A4 (LTA4)
- Leukotriene A4 (LTA4)
- Autre désignation
- Leukotriene A4 (LTA4 Produits)
- Sujet
-
Gene Name: Leukotriene A4
Gene Aliases: LT-A4
-