Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

Ribonuclease A8 Kit ELISA

Reactivité: Humain Colorimetric Sandwich ELISA 0.312 ng/mL - 20 ng/mL Tissue Homogenate
N° du produit ABIN5658501
  • Antigène Tous les produits Ribonuclease A8
    Ribonuclease A8
    Reactivité
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    0.312 ng/mL - 20 ng/mL
    Seuil minimal de détection
    0.312 ng/mL
    Application
    ELISA
    Type d'échantillon
    Tissue Homogenate
    Analytical Method
    Quantitative
    Specificité
    This assay has high sensitivity and excellent specificity for detection of Ribonuclease A8 (RNASE8). No significant cross-reactivity or interference between Ribonuclease A8 (RNASE8) and analogues was observed.
    Sensibilité
    0.109 ng/mL
  • Commentaires

    The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.

    Durée du test
    3 h
    Plaque
    Pre-coated
    Protocole
    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Ribonuclease A8 (RNASE8). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Ribonuclease A8 (RNASE8). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Ribonuclease A8 (RNASE8), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Ribonuclease A8 (RNASE8) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
    Précision du teste
    Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Ribonuclease A8 (RNASE8) were tested 20 times on one plate, respectively
    Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Ribonuclease A8 (RNASE8) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
    Intra-Assay: CV<10%
    Inter-Assay: CV<12%
    Restrictions
    For Research Use only
  • Conseil sur la manipulation
    The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
    Stock
    4 °C,-20 °C
    Stockage commentaire
    -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
    Date de péremption
    4-8 months
  • Antigène Tous les produits Ribonuclease A8
    Ribonuclease A8
    Abstract
    Ribonuclease A8 Produits
    Sujet

    Gene Name: Ribonuclease A8

    Gene Aliases: Rnase-A8, Ribonuclease,RNase A Family,8

    UniProt
    Q8TDE3
Vous êtes ici:
Support technique