SFXN1 Kit ELISA
-
- Antigène Voir toutes SFXN1 Kits ELISA
- SFXN1 (Sideroflexin 1 (SFXN1))
-
Reactivité
- Souris
- Méthode de détection
- Colorimetric
- Type de méthode
- Sandwich ELISA
- Gamme de detection
- 0.156 ng/mL - 10 ng/mL
- Seuil minimal de détection
- 0.156 ng/mL
- Application
- ELISA
- Type d'échantillon
- Tissue Homogenate
- Analytical Method
- Quantitative
- Specificité
- This assay has high sensitivity and excellent specificity for detection of Sideroflexin 1 (SFXN1). No significant cross-reactivity or interference between Sideroflexin 1 (SFXN1) and analogues was observed.
- Sensibilité
- 0.059 ng/mL
- Featured
- Discover our best selling SFXN1 Kit ELISA
- Top Product
- Discover our top product SFXN1 Kit ELISA
-
-
- Commentaires
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Durée du test
- 3 h
- Plaque
- Pre-coated
- Protocole
- The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Sideroflexin 1 (SFXN1). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Sideroflexin 1 (SFXN1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Sideroflexin 1 (SFXN1), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Sideroflexin 1 (SFXN1) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
- Précision du teste
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Sideroflexin 1 (SFXN1) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Sideroflexin 1 (SFXN1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Conseil sur la manipulation
- The Stop Solution is acidic. Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Stock
- 4 °C,-20 °C
- Stockage commentaire
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Date de péremption
- 4-8 months
-
- Antigène Voir toutes SFXN1 Kits ELISA
- SFXN1 (Sideroflexin 1 (SFXN1))
- Autre désignation
- Sideroflexin 1 (SFXN1 Produits)
- Synonymes
- zgc:100851 Kit ELISA, 2810002O05Rik Kit ELISA, A930015P12Rik Kit ELISA, f Kit ELISA, Sideroflexin 1 Kit ELISA, sideroflexin 1 Kit ELISA, sideroflexin 1 L homeolog Kit ELISA, Bm1_35025 Kit ELISA, sfxn1 Kit ELISA, sfxn1.L Kit ELISA, SFXN1 Kit ELISA, Sfxn1 Kit ELISA
- Sujet
-
Gene Name: Sideroflexin 1
Gene Aliases: TCC, Tricarboxylate carrier protein
- ID gène
- 14057
- UniProt
- Q99JR1
- Pathways
- Transition Metal Ion Homeostasis
-