WIF1 Kit CLIA
-
- Antigène Voir toutes WIF1 Kits CLIA
- WIF1 (WNT Inhibitory Factor 1 (WIF1))
-
Reactivité
- Humain
- Méthode de détection
- Chemiluminescent
- Type de méthode
- Sandwich ELISA
- Gamme de detection
- 15.62 pg/mL - 1000 pg/mL
- Seuil minimal de détection
- 15.62 pg/mL
- Application
- ELISA
- Type d'échantillon
- Plasma, Serum
- Analytical Method
- Quantitative
- Specificité
- This assay has high sensitivity and excellent specificity for detection of WNT Inhibitory Factor 1 (WIF1). No significant cross-reactivity or interference between WNT Inhibitory Factor 1 (WIF1) and analogues was observed.
- Sensibilité
- 0.55 pg/mL
- Featured
- Discover our best selling WIF1 Kit ELISA
- Top Product
- Discover our top product WIF1 Kit ELISA
-
-
- Commentaires
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Durée du test
- 2 - 3 h
- Plaque
- Pre-coated
- Protocole
- The microplate provided in this kit has been pre-coated with an antibody specific to WNT Inhibitory Factor 1 (WIF1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to WNT Inhibitory Factor 1 (WIF1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the WNT Inhibitory Factor 1 (WIF1) level in the sample or standard.,
- Précision du teste
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level WNT Inhibitory Factor 1 (WIF1) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level WNT Inhibitory Factor 1 (WIF1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Conseil sur la manipulation
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Stock
- 4 °C,-20 °C
- Stockage commentaire
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Date de péremption
- 4-8 months
-
- Antigène Voir toutes WIF1 Kits CLIA
- WIF1 (WNT Inhibitory Factor 1 (WIF1))
- Autre désignation
- WNT Inhibitory Factor 1 (WIF1 Produits)
- Synonymes
- shf Kit CLIA, GB10372 Kit CLIA, wif-1 Kit CLIA, WIF1 Kit CLIA, WIF-1 Kit CLIA, AW107799 Kit CLIA, zgc:110507 Kit CLIA, protein shifted Kit CLIA, wnt inhibitory factor 1 Kit CLIA, WNT inhibitory factor 1 Kit CLIA, Wnt inhibitory factor 1 Kit CLIA, WNT inhibitory factor 1 S homeolog Kit CLIA, LOC552805 Kit CLIA, CpipJ_CPIJ003761 Kit CLIA, wif1 Kit CLIA, WIF1 Kit CLIA, Wif1 Kit CLIA, LOC100511326 Kit CLIA, wif1.S Kit CLIA
- Sujet
-
Gene Name: WNT Inhibitory Factor 1
- Pathways
- Signalisation WNT, Positive Regulation of fat Cell Differentiation
-