WFS1 Kit CLIA
-
- Antigène Voir toutes WFS1 Kits CLIA
- WFS1 (Wolfram Syndrome 1 (WFS1))
-
Reactivité
- Souris
- Méthode de détection
- Chemiluminescent
- Type de méthode
- Sandwich ELISA
- Gamme de detection
- 156.25 pg/mL - 10000 pg/mL
- Seuil minimal de détection
- 156.25 pg/mL
- Application
- ELISA
- Type d'échantillon
- Tissue Homogenate
- Analytical Method
- Quantitative
- Specificité
- This assay has high sensitivity and excellent specificity for detection of Wolfram Syndrome Protein 1 (WFS1). No significant cross-reactivity or interference between Wolfram Syndrome Protein 1 (WFS1) and analogues was observed.
- Sensibilité
- 6 pg/mL
- Top Product
- Discover our top product WFS1 Kit ELISA
-
-
- Commentaires
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition. To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
- Durée du test
- 2 - 3 h
- Plaque
- Pre-coated
- Protocole
- The microplate provided in this kit has been pre-coated with an antibody specific to Wolfram Syndrome Protein 1 (WFS1). Standards or samples are then added to the appropriate microplate wells with a biotin-conjugated antibody specific to Wolfram Syndrome Protein 1 (WFS1). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. Then the mixture of substrate A and B is added to generate glow light emission kinetics. Upon plate development, the intensity of the emitted light is proportional to the Wolfram Syndrome Protein 1 (WFS1) level in the sample or standard.,
- Précision du teste
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Wolfram Syndrome Protein 1 (WFS1) were tested 20 times on one plate, respectively
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Wolfram Syndrome Protein 1 (WFS1) were tested on 3 different plates, 8 replicates in each plate. CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12% - Restrictions
- For Research Use only
-
- Conseil sur la manipulation
- Do not allow to contact skin or eyes. Calibrators, controls and specimen samples should be assayed in duplicate. Once the procedure has been started, all steps should be completed without interruption.
- Stock
- 4 °C,-20 °C
- Stockage commentaire
- -20°C. Bring all reagents to room temperature before beginning test. The kit may be stored at 4°C for immediate use within two days upon arrival. Reseal any unused strips with desiccant pack. Minimize freeze/thaw cycles.
- Date de péremption
- 4-8 months
-
- Antigène Voir toutes WFS1 Kits CLIA
- WFS1 (Wolfram Syndrome 1 (WFS1))
- Autre désignation
- Wolfram Syndrome Protein 1 (WFS1 Produits)
- Synonymes
- WFRS Kit CLIA, WFS Kit CLIA, WFSL Kit CLIA, CG4917 Kit CLIA, Dmel\\CG4917 Kit CLIA, GB15257 Kit CLIA, WFS1 Kit CLIA, AI481085 Kit CLIA, wolframin Kit CLIA, wfs1 Kit CLIA, wolframin ER transmembrane glycoprotein Kit CLIA, wolfram syndrome 1 Kit CLIA, wolframin Kit CLIA, Wolfram syndrome 1 (wolframin) L homeolog Kit CLIA, Wfs1 Kit CLIA, WFS1 Kit CLIA, wfs1 Kit CLIA, LOC552818 Kit CLIA, CpipJ_CPIJ013087 Kit CLIA, wfs1.L Kit CLIA
- Sujet
-
Gene Name: Wolfram Syndrome Protein 1
Gene Aliases: DFNA14, DFNA38, DFNA6, DIDMOAD, WFRS, WFS, Wolframin
- Pathways
- Sensory Perception of Sound, Carbohydrate Homeostasis, ER-Nucleus Signaling, Negative Regulation of intrinsic apoptotic Signaling, SARS-CoV-2 Protein Interactome
-