Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

BCAM Kit ELISA

BCAM Reactivité: Humain Colorimetric Sandwich ELISA 40-10000 pg/mL Cell Culture Supernatant, Plasma, Serum
N° du produit ABIN625265
  • Antigène Voir toutes BCAM Kits ELISA
    BCAM (Basal Cell Adhesion Molecule (Lutheran Blood Group) (BCAM))
    Reactivité
    • 4
    • 2
    • 2
    • 1
    • 1
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    40-10000 pg/mL
    Seuil minimal de détection
    40 pg/mL
    Application
    ELISA
    Fonction
    Human BCAM ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Type d'échantillon
    Plasma, Cell Culture Supernatant, Serum
    Analytical Method
    Quantitative
    Specificité
    This ELISA kit shows no cross-reactivity with the following cytokines tested: human Angiogenin, BDNF, BLC, CNTF, ENA- 78, FGF-4, IL-1 alpha, IL-1 beta, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-8, IL-9, IL-11, IL-12 p70, IL-12 p40, IL-13, IL-15, IP-10, FGF-4, FGF-6, FGF-7, GCSF, GDNF, GM-CSF, IFN-gamma, IGFBP-2, IGFBP-3, IGFBP-4, Leptin (OB), MCP-1, MCP-2, MCP-3, MDC, MIF, MIG, MIP-1 alpha, MIP-1 beta, MIP-1 delta, PARC, PDGF, RANTES, SCF, SDF-1 alpha, TARC, TGF-beta, TIMP-1, TIMP- 2, TNF-alpha, TNF-beta, TPO, VEGF.
    Sensibilité
    < 40 pg/mL
    Attributs du produit
    • Strip plates and additional reagents allow for use in multiple experiments
    • Quantitative protein detection
    • Establishes normal range
    • The best products for confirmation of antibody array data
    Ingrédients
    • Pre-Coated 96-well Strip Microplate
    • Wash Buffer
    • Stop Solution
    • Assay Diluent(s)
    • Lyophilized Standard
    • Biotinylated Detection Antibody
    • Streptavidin-Conjugated HRP
    • TMB One-Step Substrate
    Matériel non inclus
    • Distilled or deionized water
    • Precision pipettes to deliver 2 μL to 1 μL volumes
    • Adjustable 1-25 μL pipettes for reagent preparation
    • 100 μL and 1 liter graduated cylinders
    • Tubes to prepare standard and sample dilutions
    • Absorbent paper
    • Microplate reader capable of measuring absorbance at 450nm
    • Log-log graph paper or computer and software for ELISA data analysis
    Featured
    Discover our best selling BCAM Kit ELISA
    Top Product
    Discover our top product BCAM Kit ELISA
  • Indications d'application
    Recommended Dilution for serum and plasma samples3 - 50 fold
    Volume d'échantillon
    100 μL
    Plaque
    Pre-coated
    Protocole
    1. Prepare all reagents, samples and standards as instructed in the manual.
    2. Add 100 μL of standard or sample to each well.
    3. Incubate 2.5 h at RT or O/N at 4 °C.
    4. Add 100 μL of prepared biotin antibody to each well.
    5. Incubate 1 h at RT.
    6. Add 100 μL of prepared Streptavidin solution to each well.
    7. Incubate 45 min at RT.
    8. Add 100 μL of TMB One-Step Substrate Reagent to each well.
    9. Incubate 30 min at RT.
    10. Add 50 μL of Stop Solution to each well.
    11. Read at 450 nm immediately.
    Préparation des réactifs
    1. Bring all reagents and samples to room temperature (18 - 25 °C) before use.
      2. Sample dilution: If your samples need to be diluted, Assay Diluent C (Item L) should be used for dilution of serum/plasma/culture supernatants/urine. Suggested dilution for normal serum/plasma: 3-50 fold. Please note that levels of the target protein may vary between different specimens. Optimal dilution factors for each sample must be determined by the investigator.
      3. Assay Diluent B (Item E) should be diluted 5-fold with deionized or distilled water before use.
      4. Preparation of standard: Briefly spin the vial of Item C. Add 400 µL Assay Diluent C (Item L) into Item C vial to prepare a 50 ng/mL standard solution. Dissolve the powder thoroughly by a gentle mix. Add 100 µL BCAM standard from the vial of Item C, into a tube with 400 µL Assay Diluent C to prepare a 10,000 pg/mL standard solution. Pipette 300myl Assay Diluent C into each tube. Use the 10,000 pg/mL standard solution to produce dilution series . Mix each tube thoroughly before the next transfer. Assay Diluent C serves as the zero standard (0 pg/mL). 200 µL 200 µL 200 µL 200 µL 200 µL 200myl 100 µL standard + 400 µL 10,000 4,000 1,600 640 256 102.4 40.96 0 pg/mL pg/mL pg/mL pg/mL pg/mL pg/mL pg/mL pg/mL
      5. If the Wash Concentrate (20x) (Item B) contains visible crystals, warm to room temperature and mix gently until dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to yield 400 ml of 1x Wash Buffer.
      6. Briefly spin the Detection Antibody vial (Item F) before use. Add 100 µL of 1x Assay Diluent B (Item E) into the vial to prepare a detection antibody concentrate. Pipette up and down to mix gently (the concentrate can be stored at 4 °C for 5 days). The detection antibody concentrate should be diluted 80-fold with 1x Assay Diluent B and used in step 4 of Part VI Assay Procedure.
      7. Briefly spin the HRP-Streptavidin concentrate vial (Item G) and pipette up and down to mix gently before use. HRP-Streptavidin concentrate should be diluted 240-fold with 1x Assay Diluent B (Item E). For example: Briefly spin the vial (Item G) and pipette up and down to mix gently . Add 50 µL of HRP-Streptavidin concentrate into a tube with 12 ml 1x Assay Diluent B to prepare a 240-fold diluted HRP-Streptavidin solution (don't store the diluted solution for next day use). Mix well.
    Procédure de l'essai
    1. Bring all reagents and samples to room temperature (18 - 25 °C) before use. It is recommended that all standards and samples be run at least in duplicate.
      2. Add 100 µL of each standard (see Reagent Preparation step 2) and sample into appropriate wells. Cover well and incubate for 2.5 hours at room temperature or over night at 4 °C with gentle shaking.
      3. Discard the solution and wash 4 times with 1x Wash Solution. Wash by filling each well with Wash Buffer (300 myl) using a multi-channel Pipette or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
      4. Add 100 µL of 1x prepared biotinylated antibody (Reagent Preparation step 6) to each well. Incubate for 1 hour at room temperature with gentle shaking.
      5. Discard the solution. Repeat the wash as in step
      6. Add 100 µL of prepared Streptavidin solution (see Reagent Preparation step 7) to each well. Incubate for 45 minutes at room temperature with gentle shaking.
      7. Discard the solution. Repeat the wash as in step
      8. Add 100 µL of TMB One-Step Substrate Reagent (Item H) to each well. Incubate for 30 minutes at room temperature in the dark with gentle shaking.
      9. Add 50 µL of Stop Solution (Item I) to each well. Read at 450 nm immediately.
    Calcul des résultats

    Calculate the mean absorbance for each set of duplicate standards, controls and samples, and subtract the average zero standard optical density. Plot the standard curve on log-log graph paper or using Sigma plot software, with standard concentration on the x-axis and absorbance on the y-axis. Draw the best-fit straight line through the standard points.
    Typical Data: These standard curves are for demonstration only. A standard curve must be run with each assay. Assay Diluent C Human BCAM concentration (pg/mL) 10 100 1000 10000 O D =4 50 n m 0.01 0.1 1 10
    Sensitivity: The minimum detectable dose of BCAM is typically less than 40 pg/mL.
    Recovery: Recovery was determined by spiking various levels of BCAM into normal human serum, plasma and cell culture media. Mean recoveries are as follows: Sample Type Average % Recovery Range ( %) Serum 76.07 68-86 Plasma 86.57 80-94 Cell culture media 84.81 76-92
    Linearity: Sample Type Serum Plasma Cell Culture Media 1:2 Average % of Expected 115.9 115.6 118.5 Range ( %) 106-123 105-123 108-128 1:4 Average % of Expected 132.4 74.76 96.47 Range ( %) 123-144 67-83 77-115
    Reproducibility: Intra-Assay: CV<10 % Inter-Assay: CV<12 %

    Précision du teste
    Intra-Assay: CV< 10 % Inter-Assay: CV< 12 %
    Restrictions
    For Research Use only
  • Conseil sur la manipulation
    Avoid repeated freeze-thaw cycles.
    Stock
    -20 °C
    Stockage commentaire
    The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.
    Date de péremption
    6 months
  • Antigène Voir toutes BCAM Kits ELISA
    BCAM (Basal Cell Adhesion Molecule (Lutheran Blood Group) (BCAM))
    Autre désignation
    BCAM (BCAM Produits)
    Synonymes
    cd239 Kit ELISA, msk19 Kit ELISA, MGC81012 Kit ELISA, LU Kit ELISA, prr2 Kit ELISA, zgc:154034 Kit ELISA, 1200005K12Rik Kit ELISA, B-CAM Kit ELISA, Gplu Kit ELISA, Lu Kit ELISA, AU Kit ELISA, CD239 Kit ELISA, MSK19 Kit ELISA, basal cell adhesion molecule (Lutheran blood group) Kit ELISA, basal cell adhesion molecule (Lutheran blood group) L homeolog Kit ELISA, basal cell adhesion molecule Kit ELISA, bcam Kit ELISA, bcam.L Kit ELISA, BCAM Kit ELISA, Bcam Kit ELISA
    Sujet
    The Human BCAM (Basal Cell Adhesion Molecule ) ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of human BCAM in serum, plasma, cell culture supernatants and urine. This assay employs an antibody specific for human BCAM coated on a 96-well plate. Standards and samples are pipetted into the wells and BCAM present in a sample is bound to the wells by the immobilized antibody. The wells are washed and biotinylated anti-human BCAM antibody is added. After washing away unbound biotinylated antibody, HRP-conjugated streptavidin is pipetted to the wells. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of BCAM bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm. Reproducibility: Intra-Assay: CV<10% Inter-Assay: CV<12%.
    ID gène
    4059
    UniProt
    P50895