CEACAM1 Kit ELISA

CEACAM1 Reactivité: Humain Colorimetric Sandwich ELISA 20-15000 pg/mL Cell Culture Supernatant, Plasma, Serum
N° du produit ABIN625279
  • Antigène Voir toutes CEACAM1 Kits ELISA
    CEACAM1 (Carcinoembryonic Antigen-Related Cell Adhesion Molecule 1 (CEACAM1))
    Reactivité
    • 7
    • 3
    • 2
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    20-15000 pg/mL
    Seuil minimal de détection
    20 pg/mL
    Application
    ELISA
    Fonction
    Human CEACAM-1 ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Type d'échantillon
    Plasma, Cell Culture Supernatant, Serum
    Analytical Method
    Quantitative
    Specificité
    This ELISA kit shows no cross-reactivity with the following cytokines tested: human Angiogenin, BDNF, BLC, ENA-78, FGF- 4, IL-1 alpha, IL-1 beta, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-8, IL-9, IL-11, IL-12 p70, IL-12 p40, IL-13, IL-15, I-309, IP-10, G-CSF, GM-CSF, IFN-gamma, Leptin (OB), MCP-1, MCP-2, MCP-3, MDC, MIP-1 alpha, MIP-1 beta, MIP-1 delta, PARC, PDGF, RANTES, SCF, TARC, TGF-beta, TIMP-1, TIMP-2, TNF-alpha, TNF-beta, TPO, VEGF.
    Sensibilité
    < 20 pg/mL
    Attributs du produit
    • Strip plates and additional reagents allow for use in multiple experiments
    • Quantitative protein detection
    • Establishes normal range
    • The best products for confirmation of antibody array data
    Ingrédients
    • Pre-Coated 96-well Strip Microplate
    • Wash Buffer
    • Stop Solution
    • Assay Diluent(s)
    • Lyophilized Standard
    • Biotinylated Detection Antibody
    • Streptavidin-Conjugated HRP
    • TMB One-Step Substrate
    Matériel non inclus
    • Distilled or deionized water
    • Precision pipettes to deliver 2 μL to 1 μL volumes
    • Adjustable 1-25 μL pipettes for reagent preparation
    • 100 μL and 1 liter graduated cylinders
    • Tubes to prepare standard and sample dilutions
    • Absorbent paper
    • Microplate reader capable of measuring absorbance at 450nm
    • Log-log graph paper or computer and software for ELISA data analysis
    Featured
    Discover our best selling CEACAM1 Kit ELISA
    Top Product
    Discover our top product CEACAM1 Kit ELISA
  • Indications d'application
    Recommended Dilution for serum and plasma samples30 - 300 fold
    Volume d'échantillon
    100 μL
    Plaque
    Pre-coated
    Protocole
    1. Prepare all reagents, samples and standards as instructed in the manual.
    2. Add 100 μL of standard or sample to each well.
    3. Incubate 2.5 h at RT or O/N at 4 °C.
    4. Add 100 μL of prepared biotin antibody to each well.
    5. Incubate 1 h at RT.
    6. Add 100 μL of prepared Streptavidin solution to each well.
    7. Incubate 45 min at RT.
    8. Add 100 μL of TMB One-Step Substrate Reagent to each well.
    9. Incubate 30 min at RT.
    10. Add 50 μL of Stop Solution to each well.
    11. Read at 450 nm immediately.
    Préparation des réactifs
    1. Bring all reagents and samples to room temperature (18 - 25 °C) before use.
      2. Sample dilution: If your samples need to be diluted, Assay Diluent A (Item D) should be used for dilution of serum/plasma samples. 1x Assay Diluent B (Item E) should be used for dilution of culture supernantants and urine. Suggested dilution for normal serum/plasma: 30-300 fold. Please note that levels of the target protein may vary between different specimens. Optimal dilution factors for each sample must be determined by the investigator.
      3. Assay Diluent B should be diluted 5-fold with deionized or distilled water before use.
      4. Preparation of standard: Briefly spin the vial of Item C and then add 400 µL Assay Diluent A (for serum/plasma samples) or 1x Assay Diluent B (for cell culture supernates/urine) into Item C vial to prepare a 50 ng/mL standard. Dissolve the powder thoroughly by a gentle mix. Add 150 µL standard (50 ng/mL) from the vial of Item C, into a tube with 350 µL 1x Assay Diluent A or 1x Assay Diluent B to prepare a 15,000pg/mL standard solution. Pipette 400 µL Assay Diluent A or 1x Assay Diluent B into each tube. Use the 15,000 pg/mL standard solution to produce a dilution series . Mix each tube thoroughly before the next transfer. Assay Diluent A or 1x Assay Diluent B serves as the zero standard (0 pg/mL). 200 µL 200 µL 200 µL 200 µL 200 µL 200myl 150 Standard + 350 µL 15,000 5,000 1,667 555.6 185.2 61.73 20.58 0 pg/mL pg/mL pg/mL pg/mL pg/mL pg/mL pg/mL pg/mL
      5. If the Wash Concentrate (20x) (Item B) contains visible crystals, warm to room temperature and mix gently until dissolved. Dilute 20 ml of Wash Buffer Concentrate into deionized or distilled water to yield 400 ml of 1x Wash Buffer.
      6. Briefly spin the Detection Antibody vial (Item F) before use. Add 100 µL of 1x Assay Diluent B into the vial to prepare a detection antibody concentrate. Pipette up and down to mix gently (the concentrate can be stored at 4 °C for 5 days). The detection antibody concentrate should be diluted 80-fold with 1x Assay Diluent B and used in step 4 of Part VI Assay Procedure.
      7. Briefly spin the HRP-Streptavidin concentrate vial (Item G) and pipette up and down to mix gently before use. HRP-Streptavidin concentrate should be diluted 400-fold with 1x Assay Diluent B. For example: Briefly spin the vial (Item G) and pipette up and down to mix gently . Add 25 µL of HRP-Streptavidin concentrate into a tube with 10 ml 1x Assay Diluent B to prepare a final 400 fold diluted HRP- Streptavidin solution (don't store the diluted solution for next day use). Mix well.
    Procédure de l'essai
    1. Bring all reagents and samples to room temperature (18 - 25 °C) before use. It is recommended that all standards and samples be run at least in duplicate.
      2. Add 100 µL of each standard (see Reagent Preparation step 2) and sample into appropriate wells. Cover well and incubate for 2.5 hours at room temperature or over night at 4 °C with gentle shaking.
      3. Discard the solution and wash 4 times with 1x Wash Solution. Wash by filling each well with Wash Buffer (300 myl) using a multi-channel Pipette or autowasher. Complete removal of liquid at each step is essential to good performance. After the last wash, remove any remaining Wash Buffer by aspirating or decanting. Invert the plate and blot it against clean paper towels.
      4. Add 100 µL of 1x prepared biotinylated antibody (Reagent Preparation step 6) to each well. Incubate for 1 hour at room temperature with gentle shaking.
      5. Discard the solution. Repeat the wash as in step
      6. Add 100 µL of prepared Streptavidin solution (see Reagent Preparation step 7) to each well. Incubate for 45 minutes at room temperature with gentle shaking.
      7. Discard the solution. Repeat the wash as in step
      8. Add 100 µL of TMB One-Step Substrate Reagent (Item H) to each well. Incubate for 30 minutes at room temperature in the dark with gentle shaking.
      9. Add 50 µL of Stop Solution (Item I) to each well. Read at 450 nm immediately.
    Calcul des résultats

    Calculate the mean absorbance for each set of duplicate standards, controls and samples, and subtract the average zero standard optical density. Plot the standard curve on log-log graph paper or using Sigma plot software, with standard concentration on the x-axis and absorbance on the y-axis. Draw the best-fit straight line through the standard points.
    Typical Data: These standard curves are for demonstration only. A standard curve must be run with each assay. Assay Diluent A Human CEACAM-1 concentration (pg/mL) O D =4 50 n m 0.01 0.1 1 10 10 100 1,000 10,000 100,000 Assay Diluent B Human CEACAM-1 concentration (pg/mL) O D =4 50 n m 0.01 0.1 1 10 10 100 1,000 10,000 100,000
    Sensitivity: The minimum detectable dose of CEACAM-1 is typically less than 20 pg/mL.
    Recovery: Recovery was determined by spiking various levels human CEACAM-1 into human serum, plasma and cell culture media. Mean recoveries are as follows: Sample Type Average % Recovery Range ( %) Serum 96.92 82-112 Plasma 86.50 70-105 Cell culture media 83.49 75-90
    Linearity: Sample Type Serum Plasma Cell Culture Media 1:2 Average % of Expected 101.3 108.8 124.5 Range ( %) 90-118 93-119 117-129 1:4 Average % of Expected 119.3 85.14 134.3 Range ( %) 108-128 78-91 127-141
    Reproducibility: Intra-Assay: CV<10 % Inter-Assay: CV<12 %

    Précision du teste
    Intra-Assay: CV< 10 % Inter-Assay: CV< 12 %
    Restrictions
    For Research Use only
  • Conseil sur la manipulation
    Avoid repeated freeze-thaw cycles.
    Stock
    -20 °C
    Stockage commentaire
    The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.
    Date de péremption
    6 months
  • Antigène Voir toutes CEACAM1 Kits ELISA
    CEACAM1 (Carcinoembryonic Antigen-Related Cell Adhesion Molecule 1 (CEACAM1))
    Autre désignation
    CEACAM-1 (CEACAM1 Produits)
    Synonymes
    BGP Kit ELISA, BGP1 Kit ELISA, BGPI Kit ELISA, CD66e Kit ELISA, CEA Kit ELISA, zeh0068 Kit ELISA, hm:zeh0068 Kit ELISA, CEACAM8 Kit ELISA, CEACAM1 Kit ELISA, MGC142545 Kit ELISA, BGPR Kit ELISA, Bgp Kit ELISA, CD66a Kit ELISA, Ccam1 Kit ELISA, Bgp1 Kit ELISA, C-CAM Kit ELISA, Cc1 Kit ELISA, Cea-1 Kit ELISA, Cea-7 Kit ELISA, Cea1 Kit ELISA, Cea7 Kit ELISA, Hv-2 Kit ELISA, Hv2 Kit ELISA, MHVR Kit ELISA, MHVR1 Kit ELISA, Mhv-1 Kit ELISA, bb-1 Kit ELISA, mCEA1 Kit ELISA, mmCGM1 Kit ELISA, mmCGM1a Kit ELISA, mmCGM2 Kit ELISA, carcinoembryonic antigen related cell adhesion molecule 1 Kit ELISA, carcinoembryonic antigen related cell adhesion molecule 5 Kit ELISA, carcinoembryonic antigen-related cell adhesion molecule 1 Kit ELISA, carcinoembryonic antigen-related cell adhesion molecule 6 Kit ELISA, CEACAM1 Kit ELISA, CEACAM5 Kit ELISA, ceacam1 Kit ELISA, Ceacam1 Kit ELISA, LOC101103343 Kit ELISA
    Sujet
    The Human CEACAM-1 (Carcinoembryonic Antigen-related Cell Adhesion Molecule 1) ELISA (Enzyme-Linked Immunosorbent Assay) kit is an in vitro enzyme-linked immunosorbent assay for the quantitative measurement of human CEACAM-1 in serum, plasma, cell culture supernatants and urine. This assay employs an antibody specific for human CEACAM-1 coated on a 96-well plate. Standards and samples are pipetted into the wells and CEACAM-1 present in a sample is bound to the wells by the immobilized antibody. The wells are washed and biotinylated anti-human CEACAM-1 antibody is added. After washing away unbound biotinylated antibody, HRP-conjugated streptavidin is pipetted to the wells. The wells are again washed, a TMB substrate solution is added to the wells and color develops in proportion to the amount of CEACAM-1 bound. The Stop Solution changes the color from blue to yellow, and the intensity of the color is measured at 450 nm. Reproducibility: Intra-Assay: CV<10% Inter-Assay: CV<12%.
    ID gène
    634
    UniProt
    P13688
Vous êtes ici:
Support technique