IL17RC Kit IQ-ELISA

IL17RC Reactivité: Humain qPCR Sandwich ELISA Cell Culture Supernatant, Plasma, Serum
N° du produit ABIN6384671
  • Antigène Voir toutes IL17RC IQ-ELISA Kits
    IL17RC (Interleukin 17 Receptor C (IL17RC))
    Reactivité
    • 4
    • 4
    Humain
    Méthode de détection
    qPCR
    Type de méthode
    Sandwich ELISA
    Application
    ELISA
    Fonction
    Human Immunoquantitative (PCR-Based) IL-17 RC ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Type d'échantillon
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Semi-Quantitative
    Sensibilité
    0.005 ng/mL
    Attributs du produit
    IQ-ELISAs employ specific capture antibodies coated on a 96-well PCR plate. Standards and samples are pipetted into the wells, the target protein in the standards and samples binds to the immobilized antibody. The wells are washed and the detection affinity reagent is added to the wells where it binds to any captured antigen. The wells are washed, and primers and PCR master mix are added to each well. The plate is placed into a real time PCR instrument for cycling and measurement of DNA amplification. The cycle number where amplification is detected is proportional to the amount of affinity detection reagent that bound to captured antigen in each well.
    Ingrédients
    • IL-17 RC Microplate (Item A): 96 well PCR plate coated with anti-Human IL-17 RC
    • Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
    • Standards (Item C): 2 vials of recombinant Human IL-17 RC
    • Assay Diluent A (Item D): 30 ml diluent buffer, 0.09% sodium azide as preservative. For Standard/Sample (serum/plasma) diluent
    • Assay Diluent B (Item E): 15 ml of 5x concentrated buffer. For Standard/Sample (cell culture medium/urine) diluent
    • Detection Affinity Reagent for IL-17 RC (Item F): 2 vials of a 4x concentrated solution of anti-Human IL-17 RC affinity reagent
    • IQELISA Detection Reagent (Item G): 1.4ml of a 10x concentrated stock
    • Primer Solution (Item I): 1.7 ml vial
    • PCR Master Mix (Item J): 1.2 ml vial
    • PCR Preparation buffer (Item K): 1ml vial of 10x concentrated buffer
    • Final Wash Buffer (Item L): 10ml vial of 10x concentrated buffer
    Matériel non inclus
    • Real-time PCR instrument, Bio-Rad recommended
    • Precision pipettes to deliver 2 μL to 1 mL volumes
    • Adjustable 1-25 mL pipettes for reagent preparation
    • 100 mL and 1 liter graduated cylinders
    • Absorbent paper
    • Distilled or deionized water
    • Log-log graph paper or computer and software for data analysis
    • Tubes to prepare standard or sample dilutions
    • Heating block or water bath capable of 80°C
    Top Product
    Discover our top product IL17RC Kit ELISA
  • Indications d'application
    The Immuno-Quantitative ELISA (IQELISA) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of only 1/10th the sample volume while also providing 10x more sensitivity than a traditional ELISA.
    Commentaires

    The Immuno-Quantitative ELISA (IQELISA™) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. Also called immuno-PCR, this detection platform results in an assay that is simultaneously familiar and cutting edge. Compared to traditional ELISA, IQELISA™ enables the use of only 1/10th the sample volume while also providing 10x more sensitivity.

    Volume d'échantillon
    25 µL
    Plaque
    Pre-coated
    Protocole
    1. Prepare all reagents, samples and standards as instructed
    2. Add 25 μL standard or sample to each well. Incubate for 2.5 hours at room temperature or overnight at 4°C
    3. Add 25 μL detection affinity reagent to each well. Incubate 1 hour at room temperature
    4. Add 25μL of IQELISA Detection Reagent to each well. Incubate 1 hour
    5. Add 15μL Primer solution 10μL of PCR master mix to each well
    6. Run real-time PCR
    Restrictions
    For Research Use only
  • Stock
    4 °C,-20 °C,-80 °C
    Stockage commentaire
    May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
    Date de péremption
    6 months
  • Antigène Voir toutes IL17RC IQ-ELISA Kits
    IL17RC (Interleukin 17 Receptor C (IL17RC))
    Autre désignation
    IL-17 RC (IL17RC Produits)
    Synonymes
    IL17-RL Kit IQ-ELISA, IL17RL Kit IQ-ELISA, 1110025H02Rik Kit IQ-ELISA, Gm19850 Kit IQ-ELISA, IL-17RC Kit IQ-ELISA, IL17-RC Kit IQ-ELISA, Il17rl Kit IQ-ELISA, interleukin 17 receptor C Kit IQ-ELISA, Il17rc Kit IQ-ELISA, IL17RC Kit IQ-ELISA
    ID gène
    84818
    UniProt
    Q8NAC3
Vous êtes ici:
Support technique