Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

XIAP Kit IQ-ELISA

XIAP Reactivité: Rat qPCR Sandwich ELISA Cell Culture Supernatant, Plasma, Serum
N° du produit ABIN6385729
  • Antigène Voir toutes XIAP IQ-ELISA Kits
    XIAP (X-Linked Inhibitor of Apoptosis (XIAP))
    Reactivité
    • 7
    • 5
    • 2
    Rat
    Méthode de détection
    qPCR
    Type de méthode
    Sandwich ELISA
    Application
    ELISA
    Fonction
    Rat Immunoquantitative (PCR-Based) XIAP ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Type d'échantillon
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Semi-Quantitative
    Attributs du produit
    IQ-ELISAs employ specific capture antibodies coated on a 96-well PCR plate. Standards and samples are pipetted into the wells, the target protein in the standards and samples binds to the immobilized antibody. The wells are washed and the detection affinity reagent is added to the wells where it binds to any captured antigen. The wells are washed, and primers and PCR master mix are added to each well. The plate is placed into a real time PCR instrument for cycling and measurement of DNA amplification. The cycle number where amplification is detected is proportional to the amount of affinity detection reagent that bound to captured antigen in each well.
    Ingrédients
    • XIAP Microplate (Item A): 96 well PCR plate coated with anti-Rat XIAP
    • Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
    • Standards (Item C): 2 vials of recombinant Rat XIAP
    • Assay Diluent A (Item D): 30 ml diluent buffer, 0.09% sodium azide as preservative. For Standard/Sample (serum/plasma) diluent
    • Assay Diluent B (Item E): 15 ml of 5x concentrated buffer. For Standard/Sample (cell culture medium/urine) diluent
    • Detection Affinity Reagent for XIAP (Item F): 2 vials of a 4x concentrated solution of anti-Rat XIAP affinity reagent
    • IQELISA Detection Reagent (Item G): 1.4ml of a 10x concentrated stock
    • Primer Solution (Item I): 1.7 ml vial
    • PCR Master Mix (Item J): 1.2 ml vial
    • PCR Preparation buffer (Item K): 1ml vial of 10x concentrated buffer
    • Final Wash Buffer (Item L): 10ml vial of 10x concentrated buffer
    Matériel non inclus
    • Real-time PCR instrument, Bio-Rad recommended
    • Precision pipettes to deliver 2 μL to 1 mL volumes
    • Adjustable 1-25 mL pipettes for reagent preparation
    • 100 mL and 1 liter graduated cylinders
    • Absorbent paper
    • Distilled or deionized water
    • Log-log graph paper or computer and software for data analysis
    • Tubes to prepare standard or sample dilutions
    • Heating block or water bath capable of 80°C
    Top Product
    Discover our top product XIAP Kit ELISA
  • Indications d'application
    The Immuno-Quantitative ELISA (IQELISA) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of only 1/10th the sample volume while also providing 10x more sensitivity than a traditional ELISA.
    Commentaires

    The Immuno-Quantitative ELISA (IQELISA™) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. Also called immuno-PCR, this detection platform results in an assay that is simultaneously familiar and cutting edge. Compared to traditional ELISA, IQELISA™ enables the use of only 1/10th the sample volume while also providing 10x more sensitivity.

    Volume d'échantillon
    25 µL
    Plaque
    Pre-coated
    Protocole
    1. Prepare all reagents, samples and standards as instructed
    2. Add 25 μL standard or sample to each well. Incubate for 2.5 hours at room temperature or overnight at 4°C
    3. Add 25 μL detection affinity reagent to each well. Incubate 1 hour at room temperature
    4. Add 25μL of IQELISA Detection Reagent to each well. Incubate 1 hour
    5. Add 15μL Primer solution 10μL of PCR master mix to each well
    6. Run real-time PCR
    Restrictions
    For Research Use only
  • Stock
    4 °C,-20 °C,-80 °C
    Stockage commentaire
    May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
    Date de péremption
    6 months
  • Antigène Voir toutes XIAP IQ-ELISA Kits
    XIAP (X-Linked Inhibitor of Apoptosis (XIAP))
    Autre désignation
    XIAP (XIAP Produits)
    Synonymes
    API3 Kit IQ-ELISA, BIRC4 Kit IQ-ELISA, IAP-3 Kit IQ-ELISA, ILP1 Kit IQ-ELISA, MIHA Kit IQ-ELISA, XLP2 Kit IQ-ELISA, hIAP-3 Kit IQ-ELISA, hIAP3 Kit IQ-ELISA, api3 Kit IQ-ELISA, birc4 Kit IQ-ELISA, ilp1 Kit IQ-ELISA, miha Kit IQ-ELISA, xlp2 Kit IQ-ELISA, xxiap Kit IQ-ELISA, 1110015C02Rik Kit IQ-ELISA, Aipa Kit IQ-ELISA, Api3 Kit IQ-ELISA, Birc4 Kit IQ-ELISA, IAP3 Kit IQ-ELISA, ILP-1 Kit IQ-ELISA, mXIAP Kit IQ-ELISA, riap3 Kit IQ-ELISA, fb73d01 Kit IQ-ELISA, wu:fb73d01 Kit IQ-ELISA, zgc:91873 Kit IQ-ELISA, BIRC8 Kit IQ-ELISA, X-linked inhibitor of apoptosis Kit IQ-ELISA, X-linked inhibitor of apoptosis L homeolog Kit IQ-ELISA, XIAP Kit IQ-ELISA, xiap Kit IQ-ELISA, xiap.L Kit IQ-ELISA, Xiap Kit IQ-ELISA
    ID gène
    63879
    UniProt
    Q9R0I6
    Pathways
    Apoptose, Caspase Cascade in Apoptosis, Transition Metal Ion Homeostasis
Vous êtes ici:
Support technique