CA4 Kit IQ-ELISA
-
- Antigène Voir toutes CA4 IQ-ELISA Kits
- CA4 (Carbonic Anhydrase IV (CA4))
-
Reactivité
- Humain
- Méthode de détection
- qPCR
- Type de méthode
- Sandwich ELISA
- Application
- ELISA
- Fonction
- Human Immunoquantitative (PCR-Based) CA4 ELISA Kit for cell culture supernatants, plasma, and serum samples.
- Type d'échantillon
- Cell Culture Supernatant, Plasma, Serum
- Analytical Method
- Semi-Quantitative
- Attributs du produit
- IQ-ELISAs employ specific capture antibodies coated on a 96-well PCR plate. Standards and samples are pipetted into the wells, the target protein in the standards and samples binds to the immobilized antibody. The wells are washed and the detection affinity reagent is added to the wells where it binds to any captured antigen. The wells are washed, and primers and PCR master mix are added to each well. The plate is placed into a real time PCR instrument for cycling and measurement of DNA amplification. The cycle number where amplification is detected is proportional to the amount of affinity detection reagent that bound to captured antigen in each well.
- Ingrédients
-
- CA4 Microplate (Item A): 96 well PCR plate coated with anti-Human CA4
- Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
- Standards (Item C): 2 vials of recombinant Human CA4
- Assay Diluent A (Item D): 30 ml diluent buffer, 0.09% sodium azide as preservative. For Standard/Sample (serum/plasma) diluent
- Assay Diluent B (Item E): 15 ml of 5x concentrated buffer. For Standard/Sample (cell culture medium/urine) diluent
- Detection Affinity Reagent for CA4 (Item F): 2 vials of a 4x concentrated solution of anti-Human CA4 affinity reagent
- IQELISA Detection Reagent (Item G): 1.4ml of a 10x concentrated stock
- Primer Solution (Item I): 1.7 ml vial
- PCR Master Mix (Item J): 1.2 ml vial
- PCR Preparation buffer (Item K): 1ml vial of 10x concentrated buffer
- Final Wash Buffer (Item L): 10ml vial of 10x concentrated buffer
- Matériel non inclus
-
- Real-time PCR instrument, Bio-Rad recommended
- Precision pipettes to deliver 2 μL to 1 mL volumes
- Adjustable 1-25 mL pipettes for reagent preparation
- 100 mL and 1 liter graduated cylinders
- Absorbent paper
- Distilled or deionized water
- Log-log graph paper or computer and software for data analysis
- Tubes to prepare standard or sample dilutions
- Heating block or water bath capable of 80°C
- Top Product
- Discover our top product CA4 Kit ELISA
-
-
- Indications d'application
- The Immuno-Quantitative ELISA (IQELISA) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of only 1/10th the sample volume while also providing 10x more sensitivity than a traditional ELISA.
- Commentaires
-
The Immuno-Quantitative ELISA (IQELISA™) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. Also called immuno-PCR, this detection platform results in an assay that is simultaneously familiar and cutting edge. Compared to traditional ELISA, IQELISA™ enables the use of only 1/10th the sample volume while also providing 10x more sensitivity.
- Volume d'échantillon
- 25 µL
- Plaque
- Pre-coated
- Protocole
-
- Prepare all reagents, samples and standards as instructed
- Add 25 μL standard or sample to each well. Incubate for 2.5 hours at room temperature or overnight at 4°C
- Add 25 μL detection affinity reagent to each well. Incubate 1 hour at room temperature
- Add 25μL of IQELISA Detection Reagent to each well. Incubate 1 hour
- Add 15μL Primer solution 10μL of PCR master mix to each well
- Run real-time PCR
- Restrictions
- For Research Use only
-
- Stock
- 4 °C,-20 °C,-80 °C
- Stockage commentaire
- May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
- Date de péremption
- 6 months
-
- Antigène Voir toutes CA4 IQ-ELISA Kits
- CA4 (Carbonic Anhydrase IV (CA4))
- Autre désignation
- CA4 (CA4 Produits)
- Synonymes
- CAIV Kit IQ-ELISA, Car4 Kit IQ-ELISA, RP17 Kit IQ-ELISA, AW456718 Kit IQ-ELISA, Ca4 Kit IQ-ELISA, ca4 Kit IQ-ELISA, caiv Kit IQ-ELISA, car4 Kit IQ-ELISA, rp17 Kit IQ-ELISA, CA4 Kit IQ-ELISA, zgc:171842 Kit IQ-ELISA, carbonic anhydrase 4 Kit IQ-ELISA, carbonic anhydrase 4 S homeolog Kit IQ-ELISA, carbonic anhydrase IV a Kit IQ-ELISA, CA4 Kit IQ-ELISA, Car4 Kit IQ-ELISA, ca4 Kit IQ-ELISA, ca4.S Kit IQ-ELISA, Ca4 Kit IQ-ELISA, ca4a Kit IQ-ELISA
- ID gène
- 762
- UniProt
- P22748
-