Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

EDAR Kit IQ-ELISA

EDAR Reactivité: Souris qPCR Sandwich ELISA Cell Culture Supernatant, Plasma, Serum
N° du produit ABIN6386397
  • Antigène Voir toutes EDAR IQ-ELISA Kits
    EDAR (Ectodysplasin A Receptor (EDAR))
    Reactivité
    • 2
    • 1
    Souris
    Méthode de détection
    qPCR
    Type de méthode
    Sandwich ELISA
    Application
    ELISA
    Fonction
    Mouse Immunoquantitative (PCR-Based) EDAR ELISA Kit for cell culture supernatants, plasma, and serum samples.
    Type d'échantillon
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Semi-Quantitative
    Attributs du produit
    IQ-ELISAs employ specific capture antibodies coated on a 96-well PCR plate. Standards and samples are pipetted into the wells, the target protein in the standards and samples binds to the immobilized antibody. The wells are washed and the detection affinity reagent is added to the wells where it binds to any captured antigen. The wells are washed, and primers and PCR master mix are added to each well. The plate is placed into a real time PCR instrument for cycling and measurement of DNA amplification. The cycle number where amplification is detected is proportional to the amount of affinity detection reagent that bound to captured antigen in each well.
    Ingrédients
    • EDAR Microplate (Item A): 96 well PCR plate coated with anti-Mouse EDAR
    • Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
    • Standards (Item C): 2 vials of recombinant Mouse EDAR
    • Assay Diluent A (Item D): 30 ml diluent buffer, 0.09% sodium azide as preservative. For Standard/Sample (serum/plasma) diluent
    • Assay Diluent B (Item E): 15 ml of 5x concentrated buffer. For Standard/Sample (cell culture medium/urine) diluent
    • Detection Affinity Reagent for EDAR (Item F): 2 vials of a 4x concentrated solution of anti-Mouse EDAR affinity reagent
    • IQELISA Detection Reagent (Item G): 1.4ml of a 10x concentrated stock
    • Primer Solution (Item I): 1.7 ml vial
    • PCR Master Mix (Item J): 1.2 ml vial
    • PCR Preparation buffer (Item K): 1ml vial of 10x concentrated buffer
    • Final Wash Buffer (Item L): 10ml vial of 10x concentrated buffer
    Matériel non inclus
    • Real-time PCR instrument, Bio-Rad recommended
    • Precision pipettes to deliver 2 μL to 1 mL volumes
    • Adjustable 1-25 mL pipettes for reagent preparation
    • 100 mL and 1 liter graduated cylinders
    • Absorbent paper
    • Distilled or deionized water
    • Log-log graph paper or computer and software for data analysis
    • Tubes to prepare standard or sample dilutions
    • Heating block or water bath capable of 80°C
    Top Product
    Discover our top product EDAR Kit ELISA
  • Indications d'application
    The Immuno-Quantitative ELISA (IQELISA) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of only 1/10th the sample volume while also providing 10x more sensitivity than a traditional ELISA.
    Commentaires

    The Immuno-Quantitative ELISA (IQELISA™) kits are an innovative assay platform that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. Also called immuno-PCR, this detection platform results in an assay that is simultaneously familiar and cutting edge. Compared to traditional ELISA, IQELISA™ enables the use of only 1/10th the sample volume while also providing 10x more sensitivity.

    Volume d'échantillon
    25 µL
    Plaque
    Pre-coated
    Protocole
    1. Prepare all reagents, samples and standards as instructed
    2. Add 25 μL standard or sample to each well. Incubate for 2.5 hours at room temperature or overnight at 4°C
    3. Add 25 μL detection affinity reagent to each well. Incubate 1 hour at room temperature
    4. Add 25μL of IQELISA Detection Reagent to each well. Incubate 1 hour
    5. Add 15μL Primer solution 10μL of PCR master mix to each well
    6. Run real-time PCR
    Restrictions
    For Research Use only
  • Stock
    4 °C,-20 °C,-80 °C
    Stockage commentaire
    May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
    Date de péremption
    6 months
  • Antigène Voir toutes EDAR IQ-ELISA Kits
    EDAR (Ectodysplasin A Receptor (EDAR))
    Autre désignation
    EDAR (EDAR Produits)
    Synonymes
    rs3 Kit IQ-ELISA, edar Kit IQ-ELISA, EDAR Kit IQ-ELISA, MGC88893 Kit IQ-ELISA, DL Kit IQ-ELISA, ECTD10A Kit IQ-ELISA, ECTD10B Kit IQ-ELISA, ED1R Kit IQ-ELISA, ED3 Kit IQ-ELISA, ED5 Kit IQ-ELISA, EDA-A1R Kit IQ-ELISA, EDA1R Kit IQ-ELISA, EDA3 Kit IQ-ELISA, HRM1 Kit IQ-ELISA, dl Kit IQ-ELISA, RGD1561714 Kit IQ-ELISA, ectodysplasin A receptor Kit IQ-ELISA, ectodysplasin-A receptor Kit IQ-ELISA, edar Kit IQ-ELISA, EDAR Kit IQ-ELISA, Edar Kit IQ-ELISA
    ID gène
    13608
    UniProt
    Q9R187
    Pathways
    Tube Formation, Ubiquitin Proteasome Pathway
Vous êtes ici: