Transferrin Kit ELISA
-
- Antigène Voir toutes Transferrin (TF) Kits ELISA
- Transferrin (TF)
-
Reactivité
- Humain
- Méthode de détection
- Colorimetric
- Type de méthode
- Sandwich ELISA
- Gamme de detection
- 0.156 ng/mL - 10 ng/mL
- Seuil minimal de détection
- 0.156 ng/mL
- Application
- ELISA
- Fonction
-
The kit is a high sensitive sandwich enzyme immunoassay for in vitro quantitative measurement of transferrin in human serum, plasma, tissue homogenates, cell lysates, cell culture supernates.
We offer validation data (WB) for the kit components. So you can be sure to order a reliable ELISA kit product composed of high quality reagents. - Type d'échantillon
- Cell Culture Supernatant, Cell Lysate, Plasma, Serum, Tissue Homogenate
- Analytical Method
- Quantitative
- Specificité
- This assay has high sensitivity and excellent specificity for detection of Transferrin.
- Sensibilité
- 0.069 ng/mL
- Classe de qualité
- High Sensitivity
- Ingrédients
-
- Pre-coated, ready to use 96-well strip plate, flat buttom
- Plate sealer for 96 wells
- Reference Standard
- Standard Diluent
- Detection Reagent A
- Detection Reagent B
- Assay Diluent A
- Assay Diluent B
- Reagent Diluent (if Detection Reagent is lyophilized)
- TMB Substrate
- Stop Solution
- Wash Buffer (30 x concentrate)
- Instruction manual
- Top Product
- Discover our top product TF Kit ELISA
-
-
- Indications d'application
-
- Limited by the current condition and scientific technology, we cannot completely conduct the comprehensive identification and analysis on the raw material provided by suppliers. So there might be some qualitative and technical risks to use the kit.
- The final experimental results will be closely related to validity of the products, operation skills of the end users and the experimental environments. Please make sure that sufficient samples are available.
- Kits from different batches may be a little different in detection range, sensitivity and color developing time.
- Do not mix or substitute reagents from one kit lot to another. Use only the reagents supplied by manufacturer.
- Protect all reagents from strong light during storage and incubation. All the bottle caps of reagents should be covered tightly to prevent the evaporation and contamination of microorganism.
- There may be some foggy substance in the wells when the plate is opened at the first time. It will not have any effect on the final assay results. Do not remove microtiter plate from the storage bag until needed.
- Wrong operations during the reagents preparation and loading, as well as incorrect parameter setting for the plate reader may lead to incorrect results. A microplate plate reader with a bandwidth of 10nm or less and an optical density range of 0-3 O.D. or greater at 450 ± 10nm wavelength is acceptable for use in absorbance measurement. Please read the instruction carefully and adjust the instrument prior to the experiment.
- Even the same operator might get different results in two separate experiments. In order to get better reproducible results, the operation of every step in the assay should be controlled. Furthermore, a preliminary experiment before assay for each batch is recommended.
- Each kit has been strictly passed Q.C test. However, results from end users might be inconsistent with our in-house data due to some unexpected transportation conditions or different lab equipments. Intra-assay variance among kits from different batches might arise from above factors, too.
- Kits from different manufacturers for the same item might produce different results, since we have not compared our products with other manufacturers.
- Commentaires
-
Information on standard material:
The standard might be recombinant protein or natural protein, that will depend on the specific kit. Moreover, the expression system is E.coli or yeast or mammal cell. There is 0.05% proclin 300 in the standard as preservative.
Information on reagents:
The stop solution used in the kit is sulfuric acid with concentration of 1 mol/L. And the wash solution is TBS. The standard diluent contains 0.02 % sodium azide, assay diluent A and assay diluent B contain 0.01% sodium azide. Some kits can contain is BSA in them.
Information on antibodies:
The provided antibodies and their host vary in different kits. - Volume d'échantillon
- 100 μL
- Durée du test
- 3 h
- Plaque
- Pre-coated
- Protocole
-
- Prepare all reagents, samples and standards,
- Add 100μL standard or sample to each well. Incubate 1 hours at 37 °C,
- Aspirate and add 100μL prepared Detection Reagent A. Incubate 1 hour at 37 °C,
- Aspirate and wash 3 times,
- Add 100μL prepared Detection Reagent B. Incubate 30 minutes at 37 °C,
- Aspirate and wash 5 times,
- Add 90μL Substrate Solution. Incubate 10-20 minutes at 37 °C,
- Add 50μL Stop Solution. Read at 450nm immediately.
- Préparation des réactifs
-
- Bring all kit components and samples to room temperature (18-25 °C) before use. If the kit is not used up all at once, remove only the strips and reagents for the current experiment and leave the remaining strips and reagents in the desired condition.
- Standard - Reconstitute the standard with the Standard Diluent, keep it at room temperature for 10 minutes and shake it gently (do not let it foam). Please prepare tubes with Standard Diluent and make a dilution series. Mix each tube thoroughly before the next transfer. The last tube with Standard Diluent is the blank as 0 mg/mL.
- Detection Reagent A and Detection Reagent B - Spin or centrifuge the stock of Detection Reagent A and B briefly before use. Dilute to working concentration (1:100) with Assay Diluent A or B, respectively.
- Wash Solution - Dilute 20 mL of Wash Solution Concentrate (30x) with 580 mL of deionized or distilled water to make 600 mL of Wash Solution (1x).
- TMB Substrate - Aspirate the required amount of solution with sterile tip and do not return the residual solution back into the vial.
Note:
- Serial dilution directly in the wells is not recommended.
- Prepare standard within 15 minutes before assay. Do not dissolve the reagents directly at 37 °C.
- Detection Reagent A and B are sticky solutions, so pipette them slowly to reduce volume errors.
- Reconstitute Standard or working solutions of Detection Reagent A and B carefully according to instructions, avoiding foaming and mixing gently until crystals are completely dissolved. To minimize inaccuracy caused by pipetting, use small volumes and ensure pipettes are calibrated. It is recommended to aspirate more than 10 µL for one-time pipetting.
- The reconstituted Standard, Detection Reagent A and B can only be used once.
- When crystals have formed in the Wash Solution concentrate (30x), warm it to room temperature and mix gently until the crystals are completely dissolved.
- Contaminated water or preparation containers affect the detection result.
- Préparation de l'échantillon
-
- It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturationmay occur in these samples, leading to false results. Samples should therefore be stored for a short periodat 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thawcycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged toremove precipitates.
- If the sample type is not specified in the instructions, a preliminary test is necessary to determinecompatibility with the kit.
- If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibilityof causing a deviation due to the introduced chemical substance.The recommended dilution factor is for reference only.
- Please estimate the concentration of the samples before performing the test. If the values are not in therange of the standard curve, the optimal sample dilution for the particular experiment has to be determined.Samples should then be diluted with PBS (pH =7.0-7.2).
- Précision du teste
-
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level of target were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level of target were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV < 10%
Inter-Assay: CV < 12% - Restrictions
- For Research Use only
-
- Précaution d'utilisation
- The Stop Solution suggested for use with this kit is an acid solution. Wear eye, hand, face, and clothing protection when using this material.
- Conseil sur la manipulation
-
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5 % within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end. - Stock
- 4 °C/-20 °C
- Stockage commentaire
-
- For unopened kit: All reagents should be stored according to the labels on the vials. The Standard, Detection Reagent A, Detection Reagent B, and 96-well Strip Plate should be stored at -20 °C upon receipt, while the other reagents should be stored at 4 °C.
- For opened kits: the remaining reagents must be stored according to the above storage conditions. In addition, please return the unused wells to the foil pouch containing the desiccant and seal the foil pouch with the zipper.
- Date de péremption
- 6 months
-
- Antigène Voir toutes Transferrin (TF) Kits ELISA
- Transferrin (TF)
- Abstract
- TF Produits
- Synonymes
- ltf Kit ELISA, pro1557 Kit ELISA, pro2086 Kit ELISA, mgc107777 Kit ELISA, LOC692564 Kit ELISA, TF Kit ELISA, LOC100144362 Kit ELISA, tf Kit ELISA, LTF Kit ELISA, TFEW Kit ELISA, conalbumin Kit ELISA, tf-b Kit ELISA, MGC64306 Kit ELISA, PRO1557 Kit ELISA, PRO2086 Kit ELISA, TFQTL1 Kit ELISA, AI266983 Kit ELISA, Cd176 Kit ELISA, HP Kit ELISA, Tf Kit ELISA, Tfn Kit ELISA, hpx Kit ELISA, Trf Kit ELISA, cb285 Kit ELISA, gavi Kit ELISA, id:ibd3238 Kit ELISA, id:ibd3525 Kit ELISA, sb:cb285 Kit ELISA, wu:fb57g06 Kit ELISA, wu:fb62h02 Kit ELISA, wu:fb63h10 Kit ELISA, wu:fb64h10 Kit ELISA, zgc:112154 Kit ELISA, 143958_at Kit ELISA, CG6186 Kit ELISA, Dmel\\CG6186 Kit ELISA, TSF1 Kit ELISA, anon-EST:Posey265 Kit ELISA, tsf1 Kit ELISA, Pro-TRH Kit ELISA, IL-5 Kit ELISA, STF I Kit ELISA, TRF1 Kit ELISA, sTF1 Kit ELISA, sTf Kit ELISA, tf1 Kit ELISA, transferrin Kit ELISA, serotransferrin Kit ELISA, transferrin (ovotransferrin) Kit ELISA, transferrin L homeolog Kit ELISA, melanotransferrin Kit ELISA, transferrin-a Kit ELISA, Transferrin 1 Kit ELISA, thyrotropin releasing hormone Kit ELISA, interleukin 5 Kit ELISA, TF Kit ELISA, LOC477072 Kit ELISA, tf Kit ELISA, Tf Kit ELISA, LOC100144362 Kit ELISA, tf.L Kit ELISA, LOC5575625 Kit ELISA, Trf Kit ELISA, tfa Kit ELISA, Tsf1 Kit ELISA, TRH Kit ELISA, IL5 Kit ELISA, LOC101085148 Kit ELISA, LOC100726872 Kit ELISA, trf Kit ELISA
- Sujet
- TRF, Siderophilin, Serotransferrin, Beta-1 metal-binding globulin
- UniProt
- P02787
- Pathways
- Transition Metal Ion Homeostasis
-