BIRC2 Kit IQ-ELISA
-
- Antigène Voir toutes BIRC2 IQ-ELISA Kits
- BIRC2 (Baculoviral IAP Repeat Containing 2 (BIRC2))
-
Reactivité
- Humain
- Méthode de détection
- qPCR
- Type de méthode
- DNA-Binding ELISA
- Gamme de detection
- 48 pg/mL - 200000 pg/mL
- Seuil minimal de détection
- 48 pg/mL
- Application
- ELISA
- Fonction
- Human Immunoquantitative (PCR-Based) cIAP-1 (BIRC2/hIAP-2) ELISA Kit for cell culture supernatants, plasma, and serum samples.
- Type d'échantillon
- Cell Culture Supernatant, Plasma, Serum
- Analytical Method
- Quantitative
- Attributs du produit
- The Immuno Quantitative Enzyme Linked ImumunoSorbent Assay (IQELISA™) is an innovative new assay that combines the specificity and ease of use of an ELISA with the sensitivity of real-time PCR. This results in an assay that is simultaneously familiar and cutting edge and enables the use of lower sample volumes while also providing more sensitivity. The Human cIAP-1 (BIRC2/hIAP-2) IQELISA™ Kit is a modified ELISA assay with high sensitivity qPCR readout for the quantitative measurement of Human cIAP-1 (BIRC2/hIAP-2) in serum, plasma, and cell culture supernatants. This assay employs an antibody specific for Human cIAP-1 (BIRC2/hIAP-2) coated on a 96-well PCR plate. Standards and samples are pipetted into the wells and cIAP-1 (BIRC2/hIAP-2) present in a sample is bound to the wells by the immobilized antibody. The wells are washed and a detection affinity molecule is added to the plates. After washing away unbound detection affinity molecule, primers and a PCR master mix are added to the wells and data is collected using qPCR. Ct values obtained from the qPCR are then used to calculate the amount of antigen contained in each sample, where lower Ct values indicate a higher concentration of antigen.
- Ingrédients
-
- cIAP-1 (BIRC2/hIAP-2) Microplate (Item A): 96 well PCR plate coated with anti-Human cIAP-1 (BIRC2/hIAP-2)
- Wash Buffer I Concentrate (20x) (Item B): 25 ml of 20x concentrated solution
- Standards (Item C): 2 vials of recombinant Human cIAP-1 (BIRC2/hIAP-2)
- Assay Diluent A (Item D): 30 ml diluent buffer, 0.09% sodium azide as preservative. For Standard/Sample (serum/plasma) diluent
- Assay Diluent B (Item E): 15 ml of 5x concentrated buffer. For Standard/Sample (cell culture medium/urine) diluent
- Detection Affinity Reagent for cIAP-1 (BIRC2/hIAP-2) (Item F): 2 vials of a 4x concentrated solution of anti-Human cIAP-1 (BIRC2/hIAP-2) affinity reagent
- IQELISA Detection Reagent (Item G): 1.4ml of a 10x concentrated stock
- Primer Solution (Item I): 1.7 ml vial
- PCR Master Mix (Item J): 1.2 ml vial
- PCR Preparation buffer (Item K): 1ml vial of 10x concentrated buffer
- Final Wash Buffer (Item L): 10ml vial of 10x concentrated buffer
- Matériel non inclus
-
- Real-time PCR instrument, Bio-Rad recommended
- Precision pipettes to deliver 2 μL to 1 mL volumes
- Adjustable 1-25 mL pipettes for reagent preparation
- 100 mL and 1 liter graduated cylinders
- Absorbent paper
- Distilled or deionized water
- Log-log graph paper or computer and software for data analysis
- Tubes to prepare standard or sample dilutions
- Heating block or water bath capable of 80°C
- Featured
- Discover our best selling BIRC2 Kit ELISA
- Top Product
- Discover our top product BIRC2 Kit ELISA
-
-
- Indications d'application
- Optimal working dilution should be determined by the investigator.
- Commentaires
-
Features:
- Excellent for follow up/confirmation of antibody array data
- Pre-coated 96 well plate
- Strip plate format minimizes waste
- Complete kit includes all necessary reagents
- 10x more sensitive than ELISA
- Reproducible and reliable
- Optimized for serum, plasma, urine and cell culture medium
- 1/10th the sample volume of an ELISA
Research Applications:
- Detection of quantitative protein levels in biological fluids
- Validation of antibody array results
- Validation of biomarker discovery studies - Protocole
-
- Prepare all reagents, samples and standards as instructed
- Add 25 μL standard or sample to each well. Incubate for 2.5 hours at room temperature or overnight at 4°C
- Add 25 μL detection affinity reagent to each well. Incubate 1 hour at room temperature
- Add 25μL of IQELISA Detection Reagent to each well. Incubate 1 hour
- Add 15μL Primer solution 10μL of PCR master mix to each well
- Run real-time PCR
- Préparation des réactifs
-
Recommended Dilution for serum and plasma samples20 - 200 fold
- Restrictions
- For Research Use only
-
- Stock
- 4 °C,-20 °C,-80 °C
- Stockage commentaire
- May be stored for up to 6 months at 2° to 8°C from the date of shipment. Standard (recombinant protein) should be stored at -20°C or -80°C (recommended at -80°C) after reconstitution. Opened PCR plate or reagents may be stored for up to 1 month at 2° to 8°C. Note: the kit can be used within one year if the whole kit is stored at -20°C. Avoid repeated freeze-thaw cycles.
- Date de péremption
- 6 months
-
- Antigène Voir toutes BIRC2 IQ-ELISA Kits
- BIRC2 (Baculoviral IAP Repeat Containing 2 (BIRC2))
- Autre désignation
- cIAP-1 (BIRC2 Produits)
- Synonymes
- API1 Kit IQ-ELISA, HIAP2 Kit IQ-ELISA, Hiap-2 Kit IQ-ELISA, MIHB Kit IQ-ELISA, RNF48 Kit IQ-ELISA, c-IAP1 Kit IQ-ELISA, cIAP1 Kit IQ-ELISA, Api2 Kit IQ-ELISA, rIAP1 Kit IQ-ELISA, IAP1 Kit IQ-ELISA, ITA Kit IQ-ELISA, AW146227 Kit IQ-ELISA, Api1 Kit IQ-ELISA, Birc3 Kit IQ-ELISA, HIAP1 Kit IQ-ELISA, IAP2 Kit IQ-ELISA, MIAP1 Kit IQ-ELISA, MIAP2 Kit IQ-ELISA, MIHC Kit IQ-ELISA, cIAP2 Kit IQ-ELISA, mcIAP1 Kit IQ-ELISA, ciap-1 Kit IQ-ELISA, birc3 Kit IQ-ELISA, api1 Kit IQ-ELISA, birc2 Kit IQ-ELISA, c-iap1 Kit IQ-ELISA, ciap1 Kit IQ-ELISA, hiap-2 Kit IQ-ELISA, hiap2 Kit IQ-ELISA, mihb Kit IQ-ELISA, rnf48 Kit IQ-ELISA, baculoviral IAP repeat containing 2 Kit IQ-ELISA, baculoviral IAP repeat-containing 2 Kit IQ-ELISA, baculoviral IAP repeat containing 2 L homeolog Kit IQ-ELISA, BIRC2 Kit IQ-ELISA, Birc2 Kit IQ-ELISA, birc2 Kit IQ-ELISA, birc2.L Kit IQ-ELISA
- ID gène
- 329
- UniProt
- Q13490
- Pathways
- Apoptose, Caspase Cascade in Apoptosis, Activation of Innate immune Response, Toll-Like Receptors Cascades
-