Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

CD40 Ligand Kit ELISA

CD40LG Reactivité: Humain Colorimetric Sandwich ELISA 62.5 pg/mL - 4000 pg/mL Cell Culture Supernatant, Plasma, Serum
N° du produit ABIN6961899
  • Antigène Voir toutes CD40 Ligand (CD40LG) Kits ELISA
    CD40 Ligand (CD40LG)
    Reactivité
    • 12
    • 11
    • 6
    • 5
    • 4
    • 4
    • 3
    • 3
    • 3
    • 2
    • 2
    • 1
    • 1
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    62.5 pg/mL - 4000 pg/mL
    Seuil minimal de détection
    62.5 pg/mL
    Application
    ELISA
    Fonction
    The kit is a sandwich enzyme immunoassay technique for the in vitro quantitative measurement in various sample types.
    Type d'échantillon
    Cell Culture Supernatant, Plasma, Serum
    Analytical Method
    Quantitative
    Specificité
    This kit recognizes Human sCD40L in samples. No Significant cross-reactivity or interference between Human sCD40L and analogues was observed.
    Sensibilité
    37.5 pg/mL
    Ingrédients
    • Pre-coated, ready to use 96-well strip plate, flat buttom
    • Plate sealer for 96 wells
    • Reference Standard
    • Reference Standard & Sample Diluent
    • Biotinylated Detection Antibody (100 x concentrate)
    • HRP Conjugate (100 x concentrate)
    • Biotinylated Detection Antibody Diluent
    • HRP Conjugate Diluent
    • Substrate Reagent
    • Stop Solution
    • Wash Buffer (25 x concentrate)
    • Instruction manual
    Top Product
    Discover our top product CD40LG Kit ELISA
  • Volume d'échantillon
    100 μL
    Durée du test
    3.5 h
    Plaque
    Pre-coated
    Protocole
    1. Add 100 µL standard or sample to each well. Incubate for 90 min at 37 °C.
    2. Remove the liquid. Add 100 µL Biotinylated Detection Antibody. Incubate for 1 hour at 37 °C.
    3. Aspirate and wash 3 times.
    4. Add 100 µL HRP Conjugate. Incubate for 30 min at 37 °C.
    5. Aspirate and wash 5 times.
    6. Add 90 µL Substrate Reagent. Incubate for 15 min at 37 °C.
    7. Add 50 µL Stop Solution. Read at 450 nm immediately.
    8. Calculation of results.
    Préparation des réactifs
    1. Bring all reagents to room temperature (18~25 °C) before use. Follow the Microplate reader manual for set-up and preheat it for 15 min before OD measurement.
    2. Wash Buffer: Dilute 30 mL of Concentrated Wash Buffer with 720 mL of deionized or distilled water to prepare 750 mL of Wash Buffer.Note: if crystals have formed in the concentrate, warm it in a 40 °C water bath and mix it gently until the crystals have completely dissolved
    3. Standard working solution: Centrifuge the standard at 10,000xg for 1 min. Add 1.0 mL of Reference Standard &Sample Diluent, let it stand for 10 min and invert it gently several times. After it dissolves fully, mix it thoroughly with a pipette. This reconstitution produces a working solution of 4000 pg/mL. Then make serial dilutions as needed. The recommended dilution gradient is as follows: 4000, 2000, 1000, 500, 250, 125, 62.50, 0 pg/mL. Dilution method: Take 7 EP tubes, add 500 μLof Reference Standard & Sample Diluent to each tube. Pipette 500 μLof the 4000 pg/mL working solution to the first tube and mix up to produce a 2000 pg/mL working solution. Pipette 500 μLof the solution from the former tube into the latter one according to these steps. The illustration below is for reference. Note: the last tube is regarded as a blank. Don't pipette solution into it from the former tube.
    4. Biotinylated Detection Antibody working solution: Calculate the required amount before the experiment (100 μL/well). In preparation, slightly more than calculated should be prepared. Centrifuge the stock tube before use, dilute the 100x Concentrated Biotinylated Detection Antibody to 1xworking solution with Biotinylated Detection Antibody Diluent.
    5. Concentrated HRP Conjugate working solution: Calculate the required amount before the experiment (100 μL/well). In preparation, slightly more than calculated should be prepared. Dilute the 100x Concentrated HRP Conjugate to 1x working solution with Concentrated HRP Conjugate Diluent.
    Préparation de l'échantillon
    • It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturation may occur in these samples, leading to false results. Samples should therefore be stored for a short period at 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thaw cycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged to remove precipitates.
    • If the sample type is not specified in the instructions, a preliminary test is necessary to determine compatibility with the kit.
    • If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibility of causing a deviation due to the introduced chemical substance. The recommended dilution factor is for reference only.
    • Please estimate the concentration of the samples before performing the test. If the values are not in the range of the standard curve, the optimal sample dilution for the particular experiment has to be determined.
    Précision du teste
    Intra-assay Precision (Precision within an assay): 3 samples with low, mid range and high level Human sCD40L were tested 20 times on one plate, respectively.
    Inter-assay Precision (Precision between assays): 3 samples with low, mid range and high level Human sCD40L were tested on 3 different plates, 20 replicates in each plate.
    Both intra-CV and inter-CV are < 10 %.
    Restrictions
    For Research Use only
  • Stock
    4 °C,-20 °C
    Stockage commentaire
    1. For unopened kit: All reagents should be stored according to the labels on the vials, so they are stable up to 12 months after receipt of the kit. The Reference Standard, Biotinylated Detection Antibody, HRP Conjugate and the 96-well stripe plate should be stored at -20 °C upon receipt while the other reagents should be stored at 4 °C.
    2. For used kit: When the kit is used, the remaining reagents need to be stored according to the above storage condition. Besides, please return the unused wells to the foil pouch containing the desiccant pack, and zip-seal the foil pouch.
    Date de péremption
    12 months
  • Antigène Voir toutes CD40 Ligand (CD40LG) Kits ELISA
    CD40 Ligand (CD40LG)
    Autre désignation
    Soluble Cluster of Differentiation 40 Ligand (CD40LG Produits)
    Synonymes
    CD154 Kit ELISA, cd40l Kit ELISA, CD40L Kit ELISA, HIGM1 Kit ELISA, IGM Kit ELISA, IMD3 Kit ELISA, T-BAM Kit ELISA, TNFSF5 Kit ELISA, TRAP Kit ELISA, gp39 Kit ELISA, hCD40L Kit ELISA, CD40-L Kit ELISA, Cd40l Kit ELISA, Ly-62 Kit ELISA, Ly62 Kit ELISA, Tnfsf5 Kit ELISA, CD40 ligand Kit ELISA, TNF superfamily member 5 Kit ELISA, CD40LG Kit ELISA, cd40l Kit ELISA, Cd40lg Kit ELISA
    Sujet
    TNFSF5,CD40LG, CD154, HIGM1, IGM, IMD3, T-BAM, TRAP, Gp39
    Pathways
    Signalisation NF-kappaB, Production of Molecular Mediator of Immune Response, Cancer Immune Checkpoints
Vous êtes ici:
Blank Blank Blank Blank Blank
Blank Blank Blank Blank Blank
Support technique