Filamin A Kit ELISA
-
- Antigène Voir toutes Filamin A (FLNA) Kits ELISA
- Filamin A (FLNA) (Filamin A, alpha (FLNA))
-
Reactivité
- Humain
- Méthode de détection
- Colorimetric
- Type de méthode
- Sandwich ELISA
- Gamme de detection
- 18.75 pg/mL - 1200 pg/mL
- Seuil minimal de détection
- 18.75 pg/mL
- Application
- ELISA
- Fonction
- For the quantitative determination of human filamin-A (FLNA) concentrations in serum, plasma, tissue homogenates, cell lysates.
- Type d'échantillon
- Cell Lysate, Plasma, Serum, Tissue Homogenate
- Analytical Method
- Quantitative
- Specificité
- This assay has high sensitivity and excellent specificity for detection of human FLNA. No significant cross-reactivity or interference between human FLNA and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between human FLNA and all the analogues, therefore, cross reaction may still exist.
- Sensibilité
- 4.68 pg/mL
- Ingrédients
-
- Assay plate
- Standard
- HRP-avidin (100 x concentrate)
- Biotin-antibody (100 x concentrate)
- Sample Diluent
- HRP-avidin Diluent
- Biotin-antibody Diluent
- Wash Buffer (25 x concentrate)
- TMB Substrate
- Stop Solution
- Adhesive Strip
- Top Product
- Discover our top product FLNA Kit ELISA
-
-
- Indications d'application
- Optimal working dilution should be determined by the investigator.
- Volume d'échantillon
- 100 μL
- Durée du test
- 1 - 4.5 h
- Plaque
- Pre-coated
- Protocole
-
- Prepare reagents, samples and standards as instructed.
- Add 100 µL standard or sample to each well. Incubate 2 hours at 37 °C.
- Remove the liquid of each well, don't wash.
- Add 100 µL Biotin-antibody (1x) to each well. Incubate 1 hour at 37 °C.
- Aspirate and wash 3 times.
- Add 100 µL HRP-avidin (1x) to each well. Incubate 1 hour at 37 °C
- Aspirate and wash 5 times.
- Add 90 μL of TMB Substrate to each well. Incubate for 15-30 minutes at 37 °C. Protect from light.
- Add 50 µL Stop Solution to each well. Read at 450 nm within 5 minutes.
- Préparation des réactifs
-
- Biotin-antibody (1x) - Centrifuge the vial before opening. Biotin-antibody requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of Biotin-antibody + 990 μL of Biotin-antibody Diluent.
- HRP-avidin (1x) - Centrifuge the vial before opening. HRP-avidin requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of HRP-avidin + 990 μL of HRP-avidin Diluent.
- Wash Buffer(1x)- If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 mL of Wash Buffer Concentrate (25 x) into deionized or distilled water to prepare 500 mL of Wash Buffer (1 x).
- Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 mL of Sample Diluent. Do not substitute other diluents. This reconstitution produces a stock solution of 1200 pg/mL. Mix the standard to ensure complete reconstitution and allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making dilutions. Pipette 250 μL of Sample Diluent into each tube (S0-S6). Use the stock solution to produce a 2-fold dilution series (below). Mix each tube thoroughly before the next transfer. The undiluted Standard serves as the high standard (1200 pg/mL). Sample Diluent serves as the zero standard (0 pg/mL).
- Kindly use graduated containers to prepare the reagent. Please don't prepare the reagent directly in the Diluent vials provided in the kit.
- Bring all reagents to room temperature (18-25 °C) before use for 30 min.
- Prepare fresh standard for each assay. Use within 4 hours and discard after use.
- Making serial dilution in the wells directly is not permitted.
- Please carefully reconstitute Standards according to the instruction, and avoid foaming and mix gently until the crystals have completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10 μL for once pipetting.
- Distilled water is recommended to be used to make the preparation for reagents. Contaminated water or container for reagent preparation will influence the detection result.
- Préparation de l'échantillon
-
- It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturationmay occur in these samples, leading to false results. Samples should therefore be stored for a short periodat 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thawcycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged toremove precipitates.
- If the sample type is not specified in the instructions, a preliminary test is necessary to determinecompatibility with the kit.
- If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibilityof causing a deviation due to the introduced chemical substance.The recommended dilution factor is for reference only.
- Please estimate the concentration of the samples before performing the test. If the values are not in therange of the standard curve, the optimal sample dilution for the particular experiment has to be determined.Samples should then be diluted with PBS (pH =7.0-7.2).
Note:Recommend to dilute the serum or plasma samples with Sample Diluent (1:10) before test. The suggested 10-fold dilution can be achieved by adding 25 μL sample to 225 μL of Sample Diluent. The recommended dilution factor is for reference only. The optimal dilution factor should be determined by users according to their particular experiments. - Précision du teste
-
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess.
Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess. - Restrictions
- For Research Use only
-
- Stock
- 4 °C,-20 °C
- Stockage commentaire
- Unopened kit Store at 2 - 8°C. Do not use the kit beyond the expiration date. May be stored for up to 1 month at 2 - 8°C. Coated assay Try to keep it in a sealed aluminum foil bag, plate and avoid the damp. Standard May be stored for up to 1 month at 2 - 8° C. If Biotin-antibody don't make recent use, better keep it store at HRP-avidin -20°C. Biotin-antibody Diluent Opened kit HRP-avidin Diluent Sample May be stored for up to 1 month at 2 - 8°C. Diluent Wash Buffer TMB Substrate Stop Solution *Provided this is within the expiration date of the kit.
- Date de péremption
- 6 months
-
- Antigène Voir toutes Filamin A (FLNA) Kits ELISA
- Filamin A (FLNA) (Filamin A, alpha (FLNA))
- Autre désignation
- filamin A, alpha (actin binding protein 280) (FLNA Produits)
- Synonymes
- ABP-280 Kit ELISA, ABPX Kit ELISA, CSBS Kit ELISA, CVD1 Kit ELISA, FLN Kit ELISA, FLN-A Kit ELISA, FLN1 Kit ELISA, FMD Kit ELISA, MNS Kit ELISA, NHBP Kit ELISA, OPD Kit ELISA, OPD1 Kit ELISA, OPD2 Kit ELISA, XLVD Kit ELISA, XMVD Kit ELISA, fb98b06 Kit ELISA, wu:fb98b06 Kit ELISA, wu:fd09g03 Kit ELISA, wu:fd49a06 Kit ELISA, Dilp2 Kit ELISA, F730004A14Rik Kit ELISA, Fln1 Kit ELISA, filamin-1 Kit ELISA, RGD1560614 Kit ELISA, MGC147094 Kit ELISA, CG3937 Kit ELISA, Cher Kit ELISA, Dmel\\CG3937 Kit ELISA, Fil Kit ELISA, joy Kit ELISA, sko Kit ELISA, filamin A Kit ELISA, filamin A, alpha (actin binding protein 280) Kit ELISA, filamin, alpha Kit ELISA, filamin-A Kit ELISA, cheerio Kit ELISA, FLNA Kit ELISA, flna Kit ELISA, Flna Kit ELISA, LOC587317 Kit ELISA, cher Kit ELISA, LOC100380643 Kit ELISA
- Sujet
-
Abbreviation: FLNA
Alias: XX-FW83128A1.1, ABP-280, ABPX, DKFZp434P031, FLN, FLN1, FMD, MNS, NHBP, OPD, OPD1, OPD2, actin binding protein 280|endothelial actin-binding protein|filamin 1|non-muscle filamin
- UniProt
- P21333
- Pathways
- TCR Signaling, Maintenance of Protein Location
-