AGO2 Kit ELISA

AGO2 Reactivité: Humain Colorimetric Sandwich ELISA 25 pg/mL - 1600 pg/mL Cell Lysate, Plasma, Serum, Tissue Homogenate
N° du produit ABIN6975055
  • Antigène Voir toutes AGO2 Kits ELISA
    AGO2 (Argonaute 2 (AGO2))
    Reactivité
    • 1
    • 1
    • 1
    Humain
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    25 pg/mL - 1600 pg/mL
    Seuil minimal de détection
    25 pg/mL
    Application
    ELISA
    Fonction
    For the quantitative determination of human protein argonaute-2 (EIF2C2) concentrations in serum, plasma, tissue homogenates, cell lysates.
    Type d'échantillon
    Cell Lysate, Plasma, Serum, Tissue Homogenate
    Analytical Method
    Quantitative
    Specificité
    This assay has high sensitivity and excellent specificity for detection of human EIF2C2. No significant cross-reactivity or interference between human EIF2C2 and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between human EIF2C2 and all the analogues, therefore, cross reaction may still exist.
    Sensibilité
    6.25 pg/mL
    Ingrédients
    • Assay plate
    • Standard
    • HRP-avidin (100 x concentrate)
    • Biotin-antibody (100 x concentrate)
    • Sample Diluent
    • HRP-avidin Diluent
    • Biotin-antibody Diluent
    • Wash Buffer (25 x concentrate)
    • TMB Substrate
    • Stop Solution
    • Adhesive Strip
  • Indications d'application
    Optimal working dilution should be determined by the investigator.
    Volume d'échantillon
    100 μL
    Durée du test
    1 - 4.5 h
    Plaque
    Pre-coated
    Protocole
    1. Prepare reagents, samples and standards as instructed.
    2. Add 100 µL standard or sample to each well. Incubate 2 hours at 37 °C.
    3. Remove the liquid of each well, don't wash.
    4. Add 100 µL Biotin-antibody (1x) to each well. Incubate 1 hour at 37 °C.
    5. Aspirate and wash 3 times.
    6. Add 100 µL HRP-avidin (1x) to each well. Incubate 1 hour at 37 °C
    7. Aspirate and wash 5 times.
    8. Add 90 μL of TMB Substrate to each well. Incubate for 15-30 minutes at 37 °C. Protect from light.
    9. Add 50 µL Stop Solution to each well. Read at 450 nm within 5 minutes.
    Préparation des réactifs
    1. Biotin-antibody (1x) - Centrifuge the vial before opening. Biotin-antibody requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of Biotin-antibody + 990 μL of Biotin-antibody Diluent.
    2. HRP-avidin (1x) - Centrifuge the vial before opening. HRP-avidin requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of HRP-avidin + 990 μL of HRP-avidin Diluent.
    3. Wash Buffer (1x) - If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 mL of Wash Buffer Concentrate (25 x) into deionized or distilled water to prepare 500 mL of Wash Buffer (1 x).
    4. Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 mL of Sample Diluent. Do not substitute other diluents. This reconstitution produces a stock solution of 1600 pg/mL. Mix the standard to ensure complete reconstitution and allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making dilutions. Pipette 250 μL of Sample Diluent into each tube (S0-S6). Use the stock solution to produce a 2-fold dilution series (below). Mix each tube thoroughly before the next transfer. The undiluted Standard serves as the high standard (1600 pg/mL). Sample Diluent serves as the zero standard (0 pg/mL).
    Note:
    • Kindly use graduated containers to prepare the reagent. Please don't prepare the reagent directly in the Diluent vials provided in the kit.
    • Bring all reagents to room temperature (18-25 °C) before use for 30 min.
    • Prepare fresh standard for each assay. Use within 4 hours and discard after use.
    • Making serial dilution in the wells directly is not permitted.
    • Please carefully reconstitute Standards according to the instruction, and avoid foaming and mix gently until the crystals have completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10 μL for once pipetting.
    • Distilled water is recommended to be used to make the preparation for reagents. Contaminated water or container for reagent preparation will influence the detection result.
    Préparation de l'échantillon
    • It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturationmay occur in these samples, leading to false results. Samples should therefore be stored for a short periodat 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thawcycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged toremove precipitates.
    • If the sample type is not specified in the instructions, a preliminary test is necessary to determinecompatibility with the kit.
    • If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibilityof causing a deviation due to the introduced chemical substance.The recommended dilution factor is for reference only.
    • Please estimate the concentration of the samples before performing the test. If the values are not in therange of the standard curve, the optimal sample dilution for the particular experiment has to be determined.Samples should then be diluted with PBS (pH =7.0-7.2).
    Précision du teste
    Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess.
    Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess.
    Restrictions
    For Research Use only
  • Stock
    4 °C,-20 °C
    Stockage commentaire
    Unopened kit Store at 2 - 8°C. Do not use the kit beyond the expiration date May be stored for up to 1 month at 2 - 8°C. Coated assay Try to keep it in a sealed aluminum foil bag, plate and avoid the damp. Standard May be stored for up to 1 month at 2 - 8° C. If Biotin-antibody don't make recent use, better keep it store at HRP-avidin -20°C. Biotin-antibody Diluent Opened kit HRP-avidin Diluent Sample May be stored for up to 1 month at 2 - 8°C. Diluent Wash Buffer TMB Substrate Stop Solution *Provided this is within the expiration date of the kit.
    Date de péremption
    6 months
  • Antigène Voir toutes AGO2 Kits ELISA
    AGO2 (Argonaute 2 (AGO2))
    Autre désignation
    eukaryotic translation initiation factor 2C, 2 (AGO2 Produits)
    Synonymes
    EIF2C2 Kit ELISA, T19E23.7 Kit ELISA, T19E23_7 Kit ELISA, argonaute 2 Kit ELISA, Q10 Kit ELISA, Eif2c2 Kit ELISA, Argonaute2 Kit ELISA, eif2c1 Kit ELISA, eif2c2 Kit ELISA, 1110029L17Rik Kit ELISA, 2310051F07Rik Kit ELISA, AI225898 Kit ELISA, AL022874 Kit ELISA, AW546247 Kit ELISA, ENSMUSG00000072493 Kit ELISA, Gerp95 Kit ELISA, Gm10365 Kit ELISA, mKIAA4215 Kit ELISA, AGO2 Kit ELISA, AG02 Kit ELISA, AGO 2 Kit ELISA, Ago-2 Kit ELISA, Ago2 Kit ELISA, CG13452 Kit ELISA, CG7439 Kit ELISA, Dm Ago2 Kit ELISA, Dmel\\CG7439 Kit ELISA, ago Kit ELISA, ago-2 Kit ELISA, ago2 Kit ELISA, dAGO2 Kit ELISA, dAgo2 Kit ELISA, eIF2C2 Kit ELISA, argonaute 2, RISC catalytic component Kit ELISA, Argonaute family protein Kit ELISA, argonaute 2, RISC catalytic component L homeolog Kit ELISA, argonaute RISC catalytic subunit 2 Kit ELISA, argonaute RISC catalytic component 2 Kit ELISA, Argonaute 2 Kit ELISA, AGO2 Kit ELISA, Ago2 Kit ELISA, ago2.L Kit ELISA, ago2 Kit ELISA
    Sujet

    Abbreviation: EIF2C2

    Alias: AGO2, MGC3183, Q10, argonaute 2

    UniProt
    Q9UKV8
    Pathways
    Fc-epsilon Receptor Signaling Pathway, Regulatory RNA Pathways, EGFR Signaling Pathway, Neurotrophin Signaling Pathway, Ribonucleoprotein Complex Subunit Organization