- Fonction
- For the quantitative determination of human 3-hydroxyacyl-CoA dehydrogenase type-2 (HSD17B10) concentrations in serum, plasma, tissue homogenates, cell lysates.
- Type d'échantillon
- Cell Lysate, Plasma, Serum, Tissue Homogenate
- Analytical Method
- Quantitative
- Specificité
- This assay has high sensitivity and excellent specificity for detection of human HSD17B10. No significant cross-reactivity or interference between human HSD17B10 and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between human HSD17B10 and all the analogues, therefore, cross reaction may still exist.
- Sensibilité
- 6.25 pg/mL
- Ingrédients
-
- Assay plate
- Standard
- HRP-avidin (100 x concentrate)
- Biotin-antibody (100 x concentrate)
- Sample Diluent
- HRP-avidin Diluent
- Biotin-antibody Diluent
- Wash Buffer (25 x concentrate)
- TMB Substrate
- Stop Solution
- Adhesive Strip
- Top Product
- Discover our top product HSD17B10 Kit ELISA
-
-
- Indications d'application
- Optimal working dilution should be determined by the investigator.
- Volume d'échantillon
- 100 μL
- Durée du test
- 1 - 4.5 h
- Plaque
- Pre-coated
- Protocole
-
- Prepare reagents, samples and standards as instructed.
- Add 100 µL standard or sample to each well. Incubate 2 hours at 37 °C.
- Remove the liquid of each well, don't wash.
- Add 100 µL Biotin-antibody (1x) to each well. Incubate 1 hour at 37 °C.
- Aspirate and wash 3 times.
- Add 100 µL HRP-avidin (1x) to each well. Incubate 1 hour at 37 °C
- Aspirate and wash 5 times.
- Add 90 μL of TMB Substrate to each well. Incubate for 15-30 minutes at 37 °C. Protect from light.
- Add 50 µL Stop Solution to each well. Read at 450 nm within 5 minutes.
- Préparation des réactifs
-
- Biotin-antibody (1x) - Centrifuge the vial before opening. Biotin-antibody requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of Biotin-antibody + 990 μL of Biotin-antibody Diluent.
- HRP-avidin (1x) - Centrifuge the vial before opening. HRP-avidin requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of HRP-avidin + 990 μL of HRP-avidin Diluent.
- Wash Buffer(1x)- If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 mL of Wash Buffer Concentrate (25 x) into deionized or distilled water to prepare 500 mL of Wash Buffer (1 x).
- Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 mL of Sample Diluent. Do not substitute other diluents. This reconstitution produces a stock solution of 1600 pg/mL. Mix the standard to ensure complete reconstitution and allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making dilutions. Pipette 250 μL of Sample Diluent into each tube (S0-S6). Use the stock solution to produce a 2-fold dilution series (below). Mix each tube thoroughly before the next transfer. The undiluted Standard serves as the high standard (1600 pg/mL). Sample Diluent serves as the zero standard (0 pg/mL).
- Préparation de l'échantillon
-
- It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturationmay occur in these samples, leading to false results. Samples should therefore be stored for a short periodat 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thawcycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged toremove precipitates.
- If the sample type is not specified in the instructions, a preliminary test is necessary to determinecompatibility with the kit.
- If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibilityof causing a deviation due to the introduced chemical substance.The recommended dilution factor is for reference only.
- Please estimate the concentration of the samples before performing the test. If the values are not in therange of the standard curve, the optimal sample dilution for the particular experiment has to be determined.Samples should then be diluted with PBS (pH =7.0-7.2).
- Précision du teste
-
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess.
Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess. - Restrictions
- For Research Use only
-
- Stock
- 4 °C,-20 °C
- Stockage commentaire
- Unopened kit Store at 2 - 8°C. Do not use the kit beyond the expiration date. May be stored for up to 1 month at 2 - 8°C. Coated assay Try to keep it in a sealed aluminum foil bag, plate and avoid the damp. Standard May be stored for up to 1 month at 2 - 8° C. If Biotin-antibody don't make recent use, better keep it store at HRP-avidin -20°C. Biotin-antibody Diluent Opened kit HRP-avidin Diluent Sample May be stored for up to 1 month at 2 - 8°C. Diluent Wash Buffer TMB Substrate Stop Solution *Provided this is within the expiration date of the kit.
- Date de péremption
- 6 months
-
- Antigène Voir toutes HSD17B10 Kits ELISA
- HSD17B10 (Hydroxysteroid (17-Beta) Dehydrogenase 10 (HSD17B10))
- Autre désignation
- hydroxysteroid (17-beta) dehydrogenase 10 (HSD17B10 Produits)
- Synonymes
- hadh2 Kit ELISA, im:6899159 Kit ELISA, wu:fj61f03 Kit ELISA, zgc:101605 Kit ELISA, abad Kit ELISA, camr Kit ELISA, erab Kit ELISA, hcd2 Kit ELISA, hsd10 Kit ELISA, mhbd Kit ELISA, mrpp2 Kit ELISA, mrx17 Kit ELISA, mrx31 Kit ELISA, mrxs10 Kit ELISA, schad Kit ELISA, sdr5c1 Kit ELISA, HADH2 Kit ELISA, HSD17B10 Kit ELISA, 17b-HSD10 Kit ELISA, ABAD Kit ELISA, CAMR Kit ELISA, DUPXp11.22 Kit ELISA, ERAB Kit ELISA, HCD2 Kit ELISA, MHBD Kit ELISA, MRPP2 Kit ELISA, MRX17 Kit ELISA, MRX31 Kit ELISA, MRXS10 Kit ELISA, SCHAD Kit ELISA, SDR5C1 Kit ELISA, 17bHSD10 Kit ELISA, Ads9 Kit ELISA, Hadh2 Kit ELISA, hydroxysteroid (17-beta) dehydrogenase 10 Kit ELISA, hydroxysteroid 17-beta dehydrogenase 10 Kit ELISA, hydroxysteroid (17-beta) dehydrogenase 10 L homeolog Kit ELISA, HSD17B10 Kit ELISA, hsd17b10 Kit ELISA, hsd17b10.L Kit ELISA, Hsd17b10 Kit ELISA
- Sujet
-
Abbreviation: HSD17B10
Alias: RP3-339A18.2, 17b-HSD10, ABAD, CAMR, DUPXp11.22, ERAB, HADH2, HCD2, MHBD, MRPP2, MRX17, MRX31, MRXS10, SCHAD, SDR5C1, 17-beta-hydroxysteroid dehydrogenase type 10|3-hydroxy-2-methylbutyryl-CoA dehyd
- UniProt
- Q99714
-