BIRC3 Kit ELISA
-
- Antigène Voir toutes BIRC3 Kits ELISA
- BIRC3 (Baculoviral IAP Repeat Containing 3 (BIRC3))
-
Reactivité
- Humain
- Méthode de détection
- Colorimetric
- Type de méthode
- Sandwich ELISA
- Gamme de detection
- 37.5 pg/mL - 2400 pg/mL
- Seuil minimal de détection
- 37.5 pg/mL
- Application
- ELISA
- Fonction
- For the quantitative determination of human baculoviral IAP repeat-containing protein 3 (BIRC3) concentrations in serum, plasma, tissue homogenates.
- Type d'échantillon
- Plasma, Serum, Tissue Homogenate
- Analytical Method
- Quantitative
- Specificité
- This assay has high sensitivity and excellent specificity for detection of human BIRC3. No significant cross-reactivity or interference between human BIRC3 and analogues was observed. Note: Limited by current skills and knowledge, it is impossible for us to complete the cross-reactivity detection between human BIRC3 and all the analogues, therefore, cross reaction may still exist.
- Sensibilité
- 9.4 pg/mL
- Ingrédients
-
- Assay plate
- Standard
- HRP-avidin (100 x concentrate)
- Biotin-antibody (100 x concentrate)
- Sample Diluent
- HRP-avidin Diluent
- Biotin-antibody Diluent
- Wash Buffer (25 x concentrate)
- TMB Substrate
- Stop Solution
- Adhesive Strip
-
-
- Indications d'application
- Optimal working dilution should be determined by the investigator.
- Volume d'échantillon
- 100 μL
- Durée du test
- 1 - 4.5 h
- Plaque
- Pre-coated
- Protocole
-
- Prepare reagents, samples and standards as instructed.
- Add 100 µL standard or sample to each well. Incubate 2 hours at 37 °C.
- Remove the liquid of each well, don't wash.
- Add 100 µL Biotin-antibody (1x) to each well. Incubate 1 hour at 37 °C.
- Aspirate and wash 3 times.
- Add 100 µL HRP-avidin (1x) to each well. Incubate 1 hour at 37 °C
- Aspirate and wash 5 times.
- Add 90 μL of TMB Substrate to each well. Incubate for 15-30 minutes at 37 °C. Protect from light.
- Add 50 µL Stop Solution to each well. Read at 450 nm within 5 minutes.
- Préparation des réactifs
-
- Biotin-antibody (1x) - Centrifuge the vial before opening. Biotin-antibody requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of Biotin-antibody + 990 μL of Biotin-antibody Diluent.
- HRP-avidin (1x) - Centrifuge the vial before opening. HRP-avidin requires a 100-fold dilution. A suggested 100-fold dilution is 10 μL of HRP-avidin + 990 μL of HRP-avidin Diluent.
- Wash Buffer (1x) - If crystals have formed in the concentrate, warm up to room temperature and mix gently until the crystals have completely dissolved. Dilute 20 mL of Wash Buffer Concentrate (25 x) into deionized or distilled water to prepare 500 mL of Wash Buffer (1 x).
- Standard Centrifuge the standard vial at 6000-10000rpm for 30s. Reconstitute the Standard with 1.0 mL of Sample Diluent. Do not substitute other diluents. This reconstitution produces a stock solution of 2400 pg/mL. Mix the standard to ensure complete reconstitution and allow the standard to sit for a minimum of 15 minutes with gentle agitation prior to making dilutions. Pipette 250 μL of Sample Diluent into each tube (S0-S6). Use the stock solution to produce a 2-fold dilution series (below). Mix each tube thoroughly before the next transfer. The undiluted Standard serves as the high standard (2400 pg/mL). Sample Diluent serves as the zero standard (0 pg/mL).
- Kindly use graduated containers to prepare the reagent. Please don't prepare the reagent directly in the Diluent vials provided in the kit.
- Bring all reagents to room temperature (18-25 °C) before use for 30 min.
- Prepare fresh standard for each assay. Use within 4 hours and discard after use.
- Making serial dilution in the wells directly is not permitted.
- Please carefully reconstitute Standards according to the instruction, and avoid foaming and mix gently until the crystals have completely dissolved. To minimize imprecision caused by pipetting, use small volumes and ensure that pipettors are calibrated. It is recommended to suck more than 10 μL for once pipetting.
- Distilled water is recommended to be used to make the preparation for reagents. Contaminated water or container for reagent preparation will influence the detection result.
- Préparation de l'échantillon
-
- It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturationmay occur in these samples, leading to false results. Samples should therefore be stored for a short periodat 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thawcycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged toremove precipitates.
- If the sample type is not specified in the instructions, a preliminary test is necessary to determinecompatibility with the kit.
- If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibilityof causing a deviation due to the introduced chemical substance.The recommended dilution factor is for reference only.
- Please estimate the concentration of the samples before performing the test. If the values are not in therange of the standard curve, the optimal sample dilution for the particular experiment has to be determined.Samples should then be diluted with PBS (pH =7.0-7.2).
- Précision du teste
-
Intra-assay Precision (Precision within an assay): CV%<8% Three samples of known concentration were tested twenty times on one plate to assess.
Inter-assay Precision (Precision between assays): CV%<10% Three samples of known concentration were tested in twenty assays to assess. - Restrictions
- For Research Use only
-
- Stock
- 4 °C,-20 °C
- Stockage commentaire
- Unopened kit Store at 2 - 8°C. Do not use the kit beyond the expiration date. May be stored for up to 1 month at 2 - 8°C. Coated assay Try to keep it in a sealed aluminum foil bag, plate and avoid the damp. Standard May be stored for up to 1 month at 2 - 8° C. If Biotin-antibody don't make recent use, better keep it store at HRP-avidin -20°C. Biotin-antibody Diluent Opened kit HRP-avidin Diluent Sample May be stored for up to 1 month at 2 - 8°C. Diluent Wash Buffer TMB Substrate Stop Solution *Provided this is within the expiration date of the kit.
- Date de péremption
- 6 months
-
-
Genome-wide gene expression array identifies novel genes related to disease severity and excessive daytime sleepiness in patients with obstructive sleep apnea." dans: PLoS ONE, Vol. 12, Issue 5, pp. e0176575, (2017) (PubMed).
: "
-
Genome-wide gene expression array identifies novel genes related to disease severity and excessive daytime sleepiness in patients with obstructive sleep apnea." dans: PLoS ONE, Vol. 12, Issue 5, pp. e0176575, (2017) (PubMed).
-
- Antigène Voir toutes BIRC3 Kits ELISA
- BIRC3 (Baculoviral IAP Repeat Containing 3 (BIRC3))
- Autre désignation
- baculoviral IAP repeat-containing 3 (BIRC3 Produits)
- Synonymes
- AIP1 Kit ELISA, API2 Kit ELISA, CIAP2 Kit ELISA, HAIP1 Kit ELISA, HIAP1 Kit ELISA, MALT2 Kit ELISA, MIHC Kit ELISA, RNF49 Kit ELISA, c-IAP2 Kit ELISA, Api1 Kit ELISA, Api2 Kit ELISA, IAP1 Kit ELISA, IAP2 Kit ELISA, MIHB Kit ELISA, Birc2 Kit ELISA, HIAP2 Kit ELISA, MIAP1 Kit ELISA, MIAP2 Kit ELISA, cIAP1 Kit ELISA, cIAP2 Kit ELISA, cIAP-1 Kit ELISA, cIAP-2 Kit ELISA, AW107670 Kit ELISA, BIRC2 Kit ELISA, baculoviral IAP repeat containing 3 Kit ELISA, baculoviral IAP repeat-containing 3 Kit ELISA, baculoviral IAP repeat-containing protein 3 Kit ELISA, inhibitor of apoptosis protein-2 Kit ELISA, BIRC3 Kit ELISA, Birc3 Kit ELISA, LOC100399118 Kit ELISA, OpmnVgp074 Kit ELISA
- Sujet
-
Abbreviation: BIRC3
Alias: AIP1, API2, CIAP2, HAIP1, HIAP1, MALT2, MIHC, RNF49, c-IAP2, TNFR2-TRAF signaling complex protein|apoptosis inhibitor 2|baculoviral IAP repeat-containing protein 3|inhibitor of apoptosis protein 1|m
- UniProt
- Q13489
- Pathways
- Apoptose, Caspase Cascade in Apoptosis, Activation of Innate immune Response, Toll-Like Receptors Cascades
-