Tel:
+49 (0)241 95 163 153
Fax:
+49 (0)241 95 163 155
E-Mail:
orders@anticorps-enligne.fr

FABP1 Kit ELISA

FABP1 Reactivité: Rat Colorimetric Sandwich ELISA 3.125 ng/mL - 200 ng/mL Plasma, Serum, Urine
N° du produit ABIN7041543
  • Antigène Voir toutes FABP1 Kits ELISA
    FABP1 (Fatty Acid Binding Protein 1, Liver (FABP1))
    Reactivité
    • 6
    • 6
    • 4
    • 2
    • 2
    • 2
    • 1
    • 1
    • 1
    • 1
    • 1
    • 1
    Rat
    Méthode de détection
    Colorimetric
    Type de méthode
    Sandwich ELISA
    Gamme de detection
    3.125 ng/mL - 200 ng/mL
    Seuil minimal de détection
    3.125 ng/mL
    Application
    ELISA
    Fonction
    The kit is a sandwich enzyme immunoassay for the in vitro quantitative measurement of L-FABP in rat serum, plasma.
    Type d'échantillon
    Plasma, Serum, Urine
    Analytical Method
    Quantitative
    Ingrédients
    • ELISA Micro Plate antibody coated
    • Enzyme Conjugated Detection Antibody (100X)
    • Calibrator
    • Diluent Solution
    • Wash Solution Concentrate (20X)
    • Chromogen - Substrate Solution
    • STOP Solution
    Matériel non inclus
    1. Microplate reader with 450 ± 10nm filter.
    2. Precision single or multi-channel pipettes and disposable tips.
    3. Microcentrifuge tubes for diluting samples.
    4. Squirt bottle or Microtitre washer
    5. Deionized or distilled water.
    6. Container for Wash Solution
    7. Centrifuge for sample collection
    8. Anticoagulant for plasma collection
    9. Incubator capable of maintaining 37 °C.
    10. Microplate shaker
    Top Product
    Discover our top product FABP1 Kit ELISA
  • Volume d'échantillon
    100 μL
    Durée du test
    1 - 2 h
    Plaque
    Pre-coated
    Protocole
    In this assay the LIVER-FABP (L-FABP) present in samples reacts with the anti-L-FABP antibodies, which have been adsorbed to the surface of polystyrene microtitre wells. After the removal of unbound proteins by washing, anti-L-FABP antibodies conjugated with horseradish peroxidase (HRP) are added. These enzyme-labeled antibodies form complexes with the previously bound L-FABP. Following another washing step, the enzyme bound to the immunosorbent is assayed by the addition of a chromogenic substrate, 3,3’,5,5’-tetramethylbenzidine (TMB). The quantity of bound enzyme varies directly with the concentration of L-FABP in the sample tested; thus, the absorbance, at 450 nm, is a measure of the concentration of L-FABP in the test sample. The quantity of L-FABP in the test sample can be interpolated from the standard curve constructed from the standards, and corrected for sample dilution.
    Préparation des réactifs
    • Bring all reagents to room temperature (16°C to 25°C) before use.
    • Diluent Solution - Ready to use as supplied.
    • Wash Solution Concentrate - The Wash Solution supplied is a 20X Concentrate and must be diluted 1/20 with distilled or deionized water (1 part buffer concentrate, 19 parts dH2O). Crystal formation in the concentrate may occur when storage temperatures are low. Warming of the concentrate to 30-35°Cbefore dilution can dissolve crystals.
    • Enzyme-Antibody Conjugate - Calculate the required amount of working conjugate solution for each microtitre plate test strip by adding 10 µL Enzyme-Antibody Conjugate to 990 µL of 1X Diluent for each test strip to be used for testing. Dilute immediately before use and protect from light. Mix uniformly, but gently. Avoid foaming.
    • Pre-coated ELISA Micro Plate - Ready to use as supplied. Unseal foil pouch and remove plate from pouch. Remove all strips and wells that will not be used in the assay and place back in pouch and re-seal along with desiccant.
    • Calibrator – Prepare according to the lot specific Certificate of Analysis.
    Préparation de l'échantillon
    • It is recommended to use fresh samples without long storage, otherwise protein degradation and denaturationmay occur in these samples, leading to false results. Samples should therefore be stored for a short periodat 2 - 8 °C or aliquoted at -20 °C (≤1 month) or -80 °C (≤ 3 months). Repeated freeze-thawcycles should be avoided. Prior to assay, the frozen samples should be slowly thawed and centrifuged toremove precipitates.
    • If the sample type is not specified in the instructions, a preliminary test is necessary to determinecompatibility with the kit.
    • If a lysis buffer is used to prepare tissue homogenates or cell culture supernatant, there is a possibilityof causing a deviation due to the introduced chemical substance.The recommended dilution factor is for reference only.
    • Please estimate the concentration of the samples before performing the test. If the values are not in therange of the standard curve, the optimal sample dilution for the particular experiment has to be determined.Samples should then be diluted with PBS (pH =7.0-7.2).
    Note:
    The assay requires that each test sample be diluted before use. All samples should be assayed in duplicate each time the assay is performed. The recommended dilutions are only suggestions. Dilutions should be based on the expected concentration of the unknown sample such that the diluted sample falls within the dynamic range of the standard curve. If unsure of sample level, a serial dilution with one or two representative samples before running the entire plate is highly recommended.
    Serum samples – Recommended starting dilution is 1/5. To prepare a 1/5 dilution of a sample, transfer 50 µL of sample to 200 µL of 1X diluent. This gives you a 1/5 dilution. Mix thoroughly each stage.
    Plasma samples – Recommended starting dilution is 1/5. To prepare a 1/5 dilution of a sample, transfer 50 µL of sample to 200 µL of 1X diluent. This gives you a 1/5 dilution. Mix thoroughly each stage.
    Procédure de l'essai
    1. All samples and standards should be assayed in duplicates.
      2. The Standards and the test sample(s) should be loaded into the ELISA wells as quickly as possible to avoid a shift in OD readings. Using a multichannel pipette would reduce this occurrence. Pipette 100 μL of Standard 0 (0.0 ng/mL) in duplicate Standard 1 (3.13 ng/mL) in duplicate Standard 2 (6.25 ng/mL) in duplicate Standard 3 (12.50 ng/mL) in duplicate Standard 4 (25 ng/mL) in duplicate Standard 5 (50 ng/mL) in duplicate Standard 6 (100 ng/mL) in duplicate Standard 7 (200 ng/mL) in duplicate
      3. Pipette 100 μL of sample (in duplicate) into pre designated wells.
      4. Incubate the micro titer plate at room temperature for sixty (60 ± 2) minutes. Keep plate covered and level during incubation.
      5. Following incubation, aspirate the contents of the wells.
      6. Completely fill each well with appropriately diluted Wash Solution and aspirate. Repeat three times, for a total of four washes. If washing manually: completely fill wells with wash buffer, invert the plate then pour/shake out the contents in a waste container. Follow this by sharply striking the wells on absorbent paper to remove residual buffer. Repeat 3 times for a total of four washes.
      7. Pipette 100 μL of appropriately diluted Enzyme-Antibody Conjugate to each well. Incubate at room temperature for ten (10 ± 2) minutes. Keep plate covered in the dark and level during incubation.
      8. Wash and blot the wells as described in Steps 5/6.
      9. Pipette 100 μL of TMB Substrate Solution into each well.
      10. Incubate in the dark at room temperature for precisely ten (10) minutes.
      11. After ten minutes, add 100 μL of Stop Solution to each well.
      12. Determine the absorbance (450 nm) of the contents of each well within 30 minutes. Calibrate the plate reader to manufacturer’s specifications.
    Restrictions
    For Research Use only
  • Stock
    4 °C
    Stockage commentaire
    1. For unopened kit: All reagents should be stored according to the labels on the vials. All reagents should be stored at 4 °C for long term storage. Keep away from heat or direct sunlight.
    2. For opened kits: the remaining reagents must be stored according to the above storage conditions. In addition, please return the unused wells to the foil pouch containing the desiccant and seal the foil pouch with the zipper.
    .
    Date de péremption
    6 months
  • Antigène Voir toutes FABP1 Kits ELISA
    FABP1 (Fatty Acid Binding Protein 1, Liver (FABP1))
    Autre désignation
    L-FABP (FABP1 Produits)
    Synonymes
    FABPL Kit ELISA, L-FABP Kit ELISA, KAT4 Kit ELISA, KATIV Kit ELISA, mitAAT Kit ELISA, Fabpl Kit ELISA, Fabplg Kit ELISA, SCP Kit ELISA, SCP. Kit ELISA, p14 Kit ELISA, FABP1 Kit ELISA, FABP Kit ELISA, LFABP Kit ELISA, liver Kit ELISA, fabp1 Kit ELISA, Fabp1 Kit ELISA, FABP-1 Kit ELISA, FABPpm Kit ELISA, mAspAT Kit ELISA, fatty acid binding protein 1 Kit ELISA, glutamic-oxaloacetic transaminase 2 Kit ELISA, fatty acid binding protein 1, liver Kit ELISA, fatty acid binding protein 1a, liver Kit ELISA, fatty acid-binding protein, liver Kit ELISA, FABP1 Kit ELISA, GOT2 Kit ELISA, Fabp1 Kit ELISA, fabp1a Kit ELISA, LOC100726384 Kit ELISA
    Pathways
    Chromatin Binding, Regulation of Lipid Metabolism by PPARalpha
Vous êtes ici:
Support technique