Ig Kit ELISA
-
- Antigène Voir toutes Ig Kits ELISA
- Ig
- Épitope
- Chain lambda
-
Reactivité
- Humain
- Méthode de détection
- Colorimetric
- Type de méthode
- Sandwich ELISA
- Application
- ELISA
- Fonction
- The Human Lambda ELISA is a highly sensitive two-site enzyme-linked immunoassay (ELISA) for the quantitative determination of lambda in human biological samples.
- Analytical Method
- Quantitative
- Attributs du produit
- In this assay the lambda present in samples reacts with the anti-lambda antibodies which have been adsorbed to the surface of polystyrene microtiter wells. After the removal of unbound proteins by washing, anti-lambda antibodies conjugated with horseradish peroxidase (HRP), are added. These enzyme-labeled antibodies form complexes with the previously bound lambda. Following another washing step, the enzyme bound to the immunosorbent is assayed by the addition of a chromogenic substrate, 3,3',5,5'- tetramethylbenzidine (TMB). The quantity of bound enzyme varies directly with the concentration of lambda in the sample tested, thus, the absorbance, at 450 nm, is a measure of the concentration of lambda in the test sample. The quantity of lambda in the test sample can be interpolated from the calibration curve constructed from the calibrators, and corrected for sample dilution.
- Ingrédients
-
1. Diluent Concentrate: One bottle containing 50 mL of a 5X concentrated diluent running buffer.
2. Wash Solution Concentrate: One bottle containing 50 mL of a 20X concentrated wash solution.
3. Enzyme-Antibody Conjugate Concentrate: One vial containing 150 µL of a 100X concentrated affinity-purified anti-human lambda antibody conjugated with HRP in stabilizing buffer.
4. TMB Substrate Solution: One vial containing 12 mL of TMB and hydrogen peroxide in citric acid buffer at pH 3.3.
5. Stop Solution: One vial containing 12 mL of 0.3 M sulfuric acid. WARNING: Avoid contact with skin.
6. Microtiter Plate: Twelve removable eight-well strips in well holder frame. Wells are coated with affinity-purified anti-human lambda.
7. Human Lambda Calibrator: One vial containing Human Lambda Calibrator. - Matériel non inclus
-
Precision pipettes (2 µL to 200 µL) for making and dispensing dilutions
Test tubes
Microplate washer/aspirator
Distilled or de-ionized H2O Microplate reader
Assorted glassware for the preparation of reagents and buffer solutions
Timer
Vortex mixer - Featured
- Discover our best selling Ig Kit ELISA
- Top Product
- Discover our top product Ig Kit ELISA
-
-
- Plaque
- Pre-coated
- Préparation des réactifs
-
- Diluent Concentrate: The Diluent solution supplied is a 5X concentrate and must be diluted 1:5 with distilled or de-ionized water.
2. Wash Solution Concentrate: The Wash Solution supplied is a 20X concentrate and must be diluted 1:20 with distilled or de-ionized water. Crystal formation in the concentrate is not uncommon when storage temperatures are low. Warming of the concentrate to 30-35°C before dilution can dissolve crystals.
3. Enzyme-Antibody Conjugate Concentrate: Calculate the required amount of working conjugate solution for each microtiter plate test strip by adding 10 µL Enzyme-Antibody Conjugate to 990 µL of 1X Diluent for each test strip to be used for testing. Mix uniformly, but gently. Avoid foaming.
4. TMB Substrate Solution: Ready to use as supplied.
5. Stop Solution: Ready to use as supplied.
6. Microtiter Plate: Ready to use as supplied. Unseal microtiter pouch and remove plate from pouch. Remove all strips and wells that will not be used in the assay and place back in pouch and re-seal along with desiccant.
7. Human Lambda Calibrator: The calibrator is now at a concentration of 5.0 mg/mL. Prepare the Human Lambda Calibrators immediately prior to use according to the table below. Mix well between each step. Avoid foaming.
- Diluent Concentrate: The Diluent solution supplied is a 5X concentrate and must be diluted 1:5 with distilled or de-ionized water.
- Calcul des résultats
-
- Subtract the average background value from the test values for each sample.
2. Using the results observed for the calibrators construct a calibration curve. The appropriate curve fit is that of a four- parameter logistics curve, although a second order polynomial (quadratic) or other curve fits may also be used.
3. Interpolate test sample values from calibration curve. Correct for sample dilution factor to arrive at lambda concentration in original sample.
1. Reliable and reproducible results will be obtained when the assay procedure is carried out with a complete understanding of the information contained in the package insert instructions and with adherence to good laboratory practice.
2. Factors that might affect the performance of the assay include proper instrument function, cleanliness of glassware, quality of distilled or de-ionized water, and accuracy of reagent and sample pipettings, washing technique, incubation time or temperature.
- Subtract the average background value from the test values for each sample.
- Restrictions
- For Research Use only
-
- Stock
- 4 °C
- Stockage commentaire
-
1. Complete Kit: The expiration date for the kit is stated on the outer label. The recommended storage temperature is 4°C. Note: See long term storage recommendations below for the Human Lambda Calibrator.
2. Diluent: The 5X Diluent Concentrate is stable until the expiration date. The 1X working solution is stable for at least one week from the date of preparation. Both solutions should be stored at 4°C.
3. Wash Solution: The 20X Wash Solution Concentrate is stable until the expiration date. The 1X working solution is stable for at least one week from the date of preparation. Both solutions can be stored at room temperature (RT, 16-25°C) or at 4°C.
4. Enzyme-Antibody Conjugate: Undiluted anti-lambda-HRP conjugate should be stored at 4°C and diluted immediately prior to use. The working conjugate solution is stable for up to 8 hours.
5. TMB Substrate Solution: The TMB Substrate Solution should be stored at 4°C and is stable until the expiration date.
6. Stop Solution: The Stop Solution should be stored at 4°C and is stable until the expiration date.
7. Microtiter Plate: Anti-human lambda coated wells are stable until the expiration date, and should be stored at 4°C in the sealed foil pouch with desiccant pack.
8. Human Lambda Calibrator: Long term storage: Upon receipt, aliquot the calibrator and store them frozen. They will be stable until expiration date. Short term storage: The calibrator is stable for up to 14 days at 4°C. The working calibrator solutions should be prepared immediately prior to use and are stable for up to 8 hours. - Date de péremption
- The expiry date is stated on the label.
-
- Antigène Voir toutes Ig Kits ELISA
- Ig
- Autre désignation
- Immunoglobulin Ig (Ig Produits)
- Synonymes
- ATPIG Kit ELISA, ATPIQ Kit ELISA, A330005H02Rik Kit ELISA, AI315324 Kit ELISA, Ig Kit ELISA, ATPase phospholipid transporting 11C Kit ELISA, ATPase, class VI, type 11C Kit ELISA, ATP11C Kit ELISA, Atp11c Kit ELISA
-